10-6
Parameter Specification Table
590+ Series DC Digital Converter
Tag
Tag
Tag
Tag Name
Name
Name
Name
MMI Menu
MMI Menu
MMI Menu
MMI Menu
CE Block
CE Block
CE Block
CE Block
Range
Range
Range
Range
MN
MN
MN
MN Notes
Notes
Notes
Notes
169 FIELD ENABLED
DIAGNOSTICS
Field Control
Same as tag 4
ep
Output
170 FIELD ENABLE
SETUP PARAMETERS::FIELD CONTROL Field Control
Same as tag 4
eq
2
171 SETPOINT
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00 %
er
172 INT. GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00
es
173 PROP. GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00
et
174 FLD. WEAK ENABLE
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
Same as tag 4
eu
2
175 EMF LEAD
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.10 to 50.00
ev
176 EMF LAG
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 200.00
ew
177 EMF GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00
ex
178 MAX VOLTS
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00 %
ey
179 MIN FLD.CURRENT
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00 %
ez
2
180 SPDFBK ALM LEVEL
SETUP PARAMETERS::CALIBRATION
Calibration
0.00 to 100.00 % (h)
f0
181 RAW FIELD FBK
DIAGNOSTICS
Calibration
xxx.xx %
f1
Output
182 FIELD I CAL.
SETUP PARAMETERS::CALIBRATION
Calibration
0.9800 to 1.1000
f2
183 FIELD DEMAND
DIAGNOSTICS
Field Control
xxx.xx %
f3
Output
184 FLD.FIRING ANGLE
DIAGNOSTICS
Field Control
xxx.xx DEG
f4
Output
185 FLD.QUENCH DELAY SETUP PARAMETERS::FIELD CONTROL Field Control
0.0 to 600.0 SECS
f5
186 FLD. QUENCH MODE SETUP PARAMETERS::FIELD CONTROL Field Control
0 : QUENCH
1 : STANDBY
f6
187 RAW INPUT
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
xxx.xx %
f7
Output
188 OVER SPEED LEVEL
SETUP PARAMETERS::CALIBRATION
Calibration
0.00 to 200.00 %
f8
4
189 SCALED INPUT
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
xxx.xx %
f9
Output, 2
190 PEAK HW SLOPE
RESERVED
Reserved
-32768 to 32767
fa
2, 4
191 BEMF FBK LEAD
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
10 to 5000
fb
192 BEMF FBK LAG
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
10 to 5000
fc
193 TICK LENGTH
RESERVED
Reserved
xxxxx
fd
Output, 4
194 DISC ADAPT POT
RESERVED
Reserved
0 to 10000
fe
4
195 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 1 (B5)
Digout 1 (B5)
-300.00 to 300.00 %
ff
2
196 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 2 (B6)
Digout 2 (B6)
-300.00 to 300.00 %
fg
2
197 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 3 (B7)
Digout 3 (B7)
-300.00 to 300.00 %
fh
2
Summary of Contents for 590+ Series
Page 16: ...1 4 Getting Started 590 Series DC Digital Converter ...
Page 76: ...3 50 Installing the Converter 590 Series DC Digital Converter ...
Page 110: ...5 14 The Operator Station 590 Series DC Digital Converter ...
Page 194: ...7 10 Trips and Fault Finding 590 Series DC Digital Converter ...
Page 208: ...9 6 Control Loops 590 Series DC Digital Converter ...
Page 236: ...10 28 Parameter Specification Table 590 Series DC Digital Converter ...
Page 260: ...11 24 Technical Specifications 590 Series DC Digital Converter ...
Page 274: ...12 14 Certification for the Converter 590 Series DC Digital Converter ...
Page 300: ...15 2 The Default Application 590 Series DC Digital Converter ...
Page 308: ......