6-8
Programming Your Application
590+ Series DC Digital Converter
AUX I/O
The auxiliary I/O parameters are primarily
intended to extend the functionality of the
serial links by allowing them access to the
drive analog and digital terminals.
START, JOG and ENABLE from digital
input terminals C3, C4 and C5 respectively
connect directly to the AUX I/O block.
Output signals are then sent to the drive start
and drive enable logic and the JOG/SLACK
function block.
Aux I/O
–
START (C3)
[ 68]
–
OFF
–
DIGITAL INPUT C4
[ 69]
–
OFF
–
DIGITAL INPUT C5
[ 70]
–
OFF
–
SEQ STATUS [537]
–
0x0000
ON
–
[161] AUX START
–
ON
–
[227] AUX JOG
–
ON
–
[168] AUX ENABLE
–
OFF
–
[ 94] AUX DIGOUT 1
–
OFF
–
[ 95] AUX DIGOUT 2
–
OFF
–
[ 96] AUX DIGOUT 3
–
0.00 %
–
[128] ANOUT 1
–
0.00 %
–
[129] ANOUT 2
–
0x0000
–
[536] REM. SEQUENCE
–
FALSE
–
[535] REM. SEQ. ENABLE
–
OFF
–
[496] JOG/SLACK
–
OFF
–
[497] CURRENT CONTROL
–
MMI Menu Map
1
SETUP PARAMETERS
2
AUX I/O
AUX START
AUX JOG
AUX ENABLE
AUX DIGOUT 1
AUX DIGOUT 2
AUX DIGOUT 3
ANOUT 1
ANOUT 2
JOG/SLACK
ENABLE
REM.SEQ.ENABLE
REM.SEQUENCE
SEQ STATUS
Parameter Descriptions
START (C3)
Range: See below
Refer to the DIAGNOSTICS function block description, page 6-22.
0 : OFF
1 : ON
DIGITAL INPUT C4
Range: See below
Refer to the DIAGNOSTICS function block description, page 6-22.
0 : OFF
1 : ON
DIGITAL INPUT C5
Range: See below
Refer to the DIAGNOSTICS function block description, page 6-22.
0 : OFF
1 : ON
SEQ STATUS
Range: 0x0000 to 0xFFFF
A status word that groups important system flags together for use by remote device over a
network. (Refer to “Remote Sequencing” below).
AUX START
Range: See below
Software Start/Run command.
0 : OFF
1 : ON
AUX JOG
Range: See below
Software Jog command.
0 : OFF
1 : ON
AUX ENABLE
Range: See below
Software Enable command.
0 : OFF
1 : ON
Summary of Contents for 590+ Series
Page 16: ...1 4 Getting Started 590 Series DC Digital Converter ...
Page 76: ...3 50 Installing the Converter 590 Series DC Digital Converter ...
Page 110: ...5 14 The Operator Station 590 Series DC Digital Converter ...
Page 194: ...7 10 Trips and Fault Finding 590 Series DC Digital Converter ...
Page 208: ...9 6 Control Loops 590 Series DC Digital Converter ...
Page 236: ...10 28 Parameter Specification Table 590 Series DC Digital Converter ...
Page 260: ...11 24 Technical Specifications 590 Series DC Digital Converter ...
Page 274: ...12 14 Certification for the Converter 590 Series DC Digital Converter ...
Page 300: ...15 2 The Default Application 590 Series DC Digital Converter ...
Page 308: ......