This function block contains parameters for
configuring the port for connection to
ConfigEd Lite (or other suitable PC
programming tool), or another VSD.
SYSTEM PORT P3
This MMI menu contains parameters for transferring data to and from a PC.
P3 SETUP
This MMI menu contains communication set-up parameters for System Port P3.
5703 SUPPORT
Refer to page 6-68.
BISYNCH SUPPORT
This MMI menu contains parameters for supporting the BISYNCH protocol.
MMI Menu Map
1
SERIAL LINKS
2
SYSTEM PORT P3
DUMP MMI (TX)
UDP XFER (RX)
UDP XFER (TX)
VERSION NO.
System Port P3
0x00C0
–
[332] ERROR REPORT
–
CELite (EIASCII)
–
[130] MODE
–
0x0000
–
[329] GROUP ID
–
0x0000
–
[330] UNIT ID
–
MMI Menu Map
1
SERIAL LINKS
2
SYSTEM PORT (P3)
3
P3 SETUP
MODE
5703 SUPPORT
P3 BAUD RATE
Parameter Descriptions
ERROR REPORT
Range: 0x0000 to 0xFFFF
Displays the last error as a hexadecimal code. Writing any value to this parameter will set the
value to >00C0 (No Error). Refer to Chapter 14: “Serial Communications” - Reference for a
list of codes.
MODE
Range: See below
Four options are available:
0 : DISABLED
1 : 5703 MASTER
2 : 5703 SLAVE
3 : CELite (EIASCII)
P3 BAUD RATE
Range: See below
Four options are available:
0 : DISABLED
1 : 5703 MASTER
2 : 5703 SLAVE
3 : CELite (EIASCII)
GROUP ID
Range: 0x0000 to 0x0007
(GROUP ID (GID))
The Eurotherm protocol group identity address.
UNIT ID
Range: 0x0000 to 0x000F
(UNIT ID (UID))
The Eurotherm protocol unit identity address.
MMI Menu Map
1
SERIAL LINKS
2
SYSTEM PORT (P3)
3
P3 SETUP
4
BISYNCH SUPPORT
GROUP ID (GID)
UNIT ID (UID)
ERROR REPORT
Summary of Contents for 590+ Series
Page 16: ...1 4 Getting Started 590 Series DC Digital Converter ...
Page 76: ...3 50 Installing the Converter 590 Series DC Digital Converter ...
Page 110: ...5 14 The Operator Station 590 Series DC Digital Converter ...
Page 194: ...7 10 Trips and Fault Finding 590 Series DC Digital Converter ...
Page 208: ...9 6 Control Loops 590 Series DC Digital Converter ...
Page 236: ...10 28 Parameter Specification Table 590 Series DC Digital Converter ...
Page 260: ...11 24 Technical Specifications 590 Series DC Digital Converter ...
Page 274: ...12 14 Certification for the Converter 590 Series DC Digital Converter ...
Page 300: ...15 2 The Default Application 590 Series DC Digital Converter ...
Page 308: ......