100/180 MM GRAPHICS RECORDER: USER GUIDE
HA261742
Issue 16 Nov 04
User Guide
Page 12
2 INSTALLATION (Cont.)
Figure 2.1b Mechanical installation details -large frame unit
304.7 mm (12 in)
254 mm (10 in)
23.10mm
(0.91 in)
215.9mm
(8.5 in)
Mounting slot
(Left hand side)
65mm
(2.56in)
288.0mm
(11.34 in)
288.0mm
(11.34 in)
x
y
PANEL CUTOUT DETAILS
Vertical
MAXIMUM INSTALLED ANGLE
Hard disk option: vertical panels only
Floppy disk option: a = b =15 degrees
Otherwise: a = b = 45 degrees max
277.0 mm
(10.9) in
View on underside
View on right hand side
277.0 mm
(10.9) in
65mm
(2.56in)
PANEL MOUNTING
x = 25 mm (1 inch)
y = 12.5 mm (0.5 in)
Minimum recommended inter-unit spacing
Side clamps
Top/bottom clamps
x = 12.5 mm (0.5 in)
y = 25 mm (1 inch)
a˚
b˚
Flap
open
Open flap for access to disk/pc card