100/180 MM GRAPHICS RECORDER: USER GUIDE
User Guide
Page 121
HA261742
Issue 16 Nov 04
ANNEX A: SPECIFICATION
INSTALLATION CATEGORY AND POLLUTION DEGREE
This product has been designed to conform to BS EN61010 installation category II and pollution degree 2. These are
defined as follows:
Installation category II
The rated impulse voltage for equipment on nominal 230V ac mains is 2500V.
Pollution degree 2
Normally, only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by conden-
sation shall be expected.