100/180 MM GRAPHICS RECORDER: USER GUIDE
HA261742
Issue 16 Nov 04
User Guide
Page 146
Figure B10h Menu structure sheet 8 (Options Menu 1)
B10 MENU STRUCTURE (Cont.)
See Figure B10i
Enable
Batch mode
Batch Fields
Field 1
On start log 4
On stop log
On new clear
1
1
Name files by batch
Start/Stop
4
Batch Number:
Apply
Discard
Field 2
Customer Name:
Field 3
Operator Name:
Field 4
Supervisor:
Group
Scope
Group
1) Group 1
Select
Instrument
or Group
Select
Start/Stop
or Continuous
Batch number:
Use Counter
Counter
Counter 1
Select
Counter or Text
Select Counter
(Appears only if 'Use
Counter' selected)
Batch
(Options Manual, section 1)
Apply Discard
Select Required maths function
Function
fValue
Fvalue of
Sterilizing Temp
121.1
Low cut off
Descriptor
Fo 1
Scale Low
0
Mins
Select Constant,
Input Channel,
Maths channel,
Totaliser or Counter
Scale Type
None
Zone low
0
Zone high
Max Decimal Digits
2
Colour
Alarm Number
1
Enable
Off
Job Number
1
Category
No Action
Select job category
Select: Off,
Unlatched,
Latched,
Trigger
Select Job number
26
Channel 1
75
%
100
%
Maths Number
1) Fo 1
Select maths
channel number
Value
Current value
32.65
Reset now
Mins
Reset button appears only
for resettable functions
PV Format
Numeric
Select Alarm number
Temperature interval
10
Units
Mins
Scale high
60
Select None, Linear or Log (if log
scales option fitted)
Select Numeric,
Elapsed Time or Scientific
A/B Switching
Maths
(Options Manual section 3)
Apply
Discard
Totaliser Number
1) Totaliser 1
Select totaliser
number
Enable
Select Alarm number
Alarm Number
1
Enable
Off
Job Number
1
Category
No Action
Select: Off,
Unlatched,
Latched,
Trigger
Select Job number
Select Job category
Value
Total of
Low cut off
High cut off
Units
Preset
Preset now
ch1
123456
Select channel etc. to be totalised
0
999999
Units
0
ch units
ch units
Units of channel
being totalised
Units (totaliser)
Period scaler
1
Unit scaler
1
Descriptor
Totaliser 1
Units (totaliser)
Scale Low
0
Scale High
1
Units (totaliser)
Units (totaliser)
Zone Low
1
Zone High
100
%
%
Max Decimal Digits
4
Colour
0
Scale Type
None
Select None, Linear or Log (if log
scales option fitted)
PV format
Numeric
Select Numeric or Scientific
Totaliser
(Options Manual, section 4)
A/B Switching
25
LocalHost@Domain
60
Seconds
1) List1
List1
1) Email1
Email1
SMTP (Email)
1) Message 1
Apply
Discard
Mail Server
Port Number
Sender
Errors To
Retry Time
Recipient List
Descriptor
Rcpt1
Rcpt2
Rcpt3
Rcpt4
Rcpt5
Rcpt6
Rcpt7
Rcpt8
Rcpt9
Rcpt10
Email Number
Descriptor
Protocol
Subject
Text
Include Message
Message
(Options manual Section 11)
Apply
Discard
Counter number
1) Counter 1
Select counter
number
Enable
Select Alarm number
Alarm Number
1
Enable
Off
Job Number
1
Category
No Action
Select: Off,
Unlatched,
Latched,
Trigger
Select Job number
Select Job category
Value
Units
Preset
Preset now
OFF
Units
0
Units
Descriptor
Counter 1
Units
Scale Low
0
Scale High
1
Units
Units
Zone Low
0
Zone High
100
%
%
Colour
0
Scale Type
None
A/B Switching
Select None orLinear
Counters
(Options Manual, section 5)
Timer number
1) Timer 1
Select timer
Enable
Remaining
Start now
00:00:00
Descriptor
Timer 1
Self start
Date
Month
Repeat in
00:00:00
Reset now
Any
Any
Apply
Discard
Second
Duration
Job Number
Minute
Repeat after
1
Category
No Action
Select Job number
Select Job
category
Hour
Any
Any
Any
60
Seconds
0
Seconds
These fields appear
only if 'Self start' is
enabled.
Timers
(Options manual, section 6)
Options
(Section 4.3.10)
(currently 0)
Apply
Discard
Autoconfigure
Fitted channels 24
Events 96
Event Buttons 96
Totalisers 6
Counters 6
Timers 6
Maths 12
Groups 6
Alarms per 4
Batch Enabled
Circular Trend Enabled
Auditor Pack Enabled
Security Manager Enabled
Remove Viewer level Full
Remote Viewers 4
Screen Builder Full
File transfer protocol 4
Modbus/TCP clients 2
Messages 24
Serial Comms Enabled
Adaptive Recording Enabled
User Linearisations 4
Logarithmic Scales Enabled
Master Comms Slaves 16
Output Channels 48
Demand Writes 48
Emails 24
Reports 10
Archive CSV Enabled
Relay Boards 1
Relays on board 1 3
Event Input Boards 2
(currently 0)
Batch
Maths
Totalisers
Counters
Timers
Emails
Reports
Options
See
Figures B10c, B10d,
B10i and B10j for other
configuration items
Archive
System
Save/Restore
Config
Security Network
See Figure B10b
See
Figure
B10e
See
Figure
B10f
See
Figure
B10g