ETLU4G03
Rev. 003
In the upper part of this page the user sets the Station ID, which identifies the transmitter unit of interest
when the SMS is sent.
It is possible to enable up to 16 telephone numbers to receive the SMS. To add a new telephone number
write the number in the appropriate field and push “Apply Changes” button. To delete a number on the
list, tick the “Clear” box next to the number and push “Apply Changes” button.
The “GSM Status Configuration” list shows the info reported when a “Status” SMS is received. The user
can choose the items of interest from this list.
Through “GSM Alarm Configuration” list the user can set which type of Alarm event have to be reported
by an automatic SMS when the corresponding alarm status occurs.
Through “Power on/off SMS Delay” the user sets the delay (in seconds) between the mains turn-on/off
and the time at which the SMS is sent to the user. This delay allows to avoid a continuous traffic of SMS
in case of unstable mains.