Page 1: ...USER MANUAL W DMX Micro T 1 TRX G5 ...

Page 2: ...e without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the content accordingly Intended Audience Any person installing operating and or maintaining this product should completely read through the guide that shipped with the product as well as t...

Page 3: ...d Australia 1 Safety Notes 2 Personal Safety 2 Power and Wiring 2 Operation 2 2 Introduction 3 Description 3 Features 3 Product Overview 3 Product Dimensions 4 3 Setup 5 AC Power 5 AC Plug 5 Battery Notes 5 5 GHz 5 RDM 5 4 Operation 6 User Interface 6 Basic Setup 7 Linking Devices 7 Unlinking Devices 7 Flex Mode 8 5 Technical Information 9 Product Maintenance 9 6 Technical Specifications 10 Return...

Page 4: ...ed including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RF Exposure Warning for North America and Australia Warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be inst...

Page 5: ...ys make sure you are connecting the product to the proper voltage in accordance with the specifications in this manual or on the product s specification label Never disconnect this product by pulling or tugging on the power cable Operation Do not operate this product if there is damage on the housing or cables Have the damaged parts replaced by an authorized technician at once The maximum ambient ...

Page 6: ...r mode Indicator LEDs easily show signal strength battery life and transceiver or receiver mode Features Transmit and receive 1 universe of W DMX and RDM protocols Power with included 5 V USB power supply or 4 AAA batteries not included Batteries last for up to 8 hours in receiver mode and 4 hours in transceiver mode Built in indicator lights for signal and battery strength and operation modes Can...

Page 7: ...Page 4 of 12 W DMX Micro T 1 TRX G5 User Manual Rev Introduction Product Dimensions 3 94 in 100 mm 2 56 in 65 mm 1 57 in 40 mm ...

Page 8: ...ith the W DMX Dongle and the downloadable W DMX Configurator software available at https wirelessdmx com download To enable 5 GHz in the W DMX Configurator software interface 1 Go to the Device Settings tab 2 Choose Enable 5 8 GHz and click the drop down box next to it 3 Choose On RDM Remote Device Management RDM is a standard for allowing DMX enabled devices to communicate bi directionally along ...

Page 9: ... the W DMX Micro T 1 TRX G5 TX W DMX Micro T 1 TRX G5 is operating as a transmitter see Flex Mode RX W DMX Micro T 1 TRX G5 is operating as a receiver see Flex Mode LINK On a transmitter indicates it is ready to establish a link On a receiver Light off no active link Light on the device is paired to a transmitter Light blinking the device has lost its link either the transmitter is out of range or...

Page 10: ...receivers follow the instructions above but power on only the devices that need to be paired up and turn off all the receivers that do not need to be paired up Unlinking Devices There are two ways to unlink devices individual or group unlink Individual unlink Press and hold the yellow function button on each receiver for 5 seconds The LINK LED should turn off Group unlink Press and hold the yellow...

Page 11: ...s used in Transmit mode TX or Receive mode RX To switch between these two modes 1 Disconnect the power cable 2 Press and hold the yellow function button on the front panel 3 While holding the button reconnect the power cable 4 Release the yellow function button The TX LED will turn off and the RX LED will turn on if switching from Transmit mode to Receive mode and vice versa if switching from Rece...

Page 12: ...eased mechanical wear To clean the product 1 Unplug the product from power and switch off 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cott...

Page 13: ... Voltage Selection Switching internal 100 to 230 VAC 50 60 Hz Auto ranging Parameter Values Consumption 9 VDC Operating current 1 A Power I O U S Worldwide UK Europe Power input connector Micro USB Micro USB Power cord plug Edison U S Local plug Battery type Battery Life Receiver Mode Battery Life Transceiver Mode AAA 8 hours 4 hours DMX Connectors XLR 5 pin male Maximum External Temperature 113 F...

Page 14: ...vice request Clearly label the package with an RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequat...

Page 15: ...u Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Chauvet Europe BVBA Address Stokstraat 18 Email BNLtech chauvetlighting eu 9770 Kruishoutem Belgium Website www chauvetprofessional eu Voice 32 9 388 93 97 Chauvet France Address 3 Rue Ampère 91380 Chilly Mazarin Email FRtech chauvetlighting fr France Web...