8
JP10
N.C.
JP4
JP5
JP6
N.C.
12Vdc
24Vac
24Vdc
+A
C
+A
C
+AC -0AC
12Vdc
24Vdc
24Vca
- 0
AC
- 0
AC
JP4
JP5
JP6
N.C.
12Vdc
24Vac
24Vdc
+A
C
+A
C
+AC -0AC
12Vdc
24Vdc
24Vca
- 0
AC
- 0
AC
JP4
JP5
JP6
N.C.
3.7
SAFETY EDGE
3.7.1 Mechanical safety edge in CLOSING
Wire the safety edge to
23 - 24
, terminal
JP10
.
•
If the contact is broken during
CLOSING
, the
gate stops and reverses.
•
If the contact is broken during
OPENING
, the
gate keeps on working normally
Mechanical safety edge + photocells in CLOSING
Wire the safety edge and the N.C. contact of the
photocell in series.
•
If the contact is broken during
CLOSING
, the gate
stops and reverses.
•
If the contact is broken during
OPENING
, the gate
keeps on working normally.
3.7.2 Mechanical safety edge in OPENING
Wire the safety edge to
6 – 9
, terminal
JP5
.
•
If the contact is broken during
OPENING
,
he gate stops and reverses after 3 sec.
•
If the contact is broken during
CLOSING
,
the gate keeps on working normally.
Mechanical safety edge + photocells in OPENING
Wire the safety edge and the N.C. contact of t
he photocell in series.
•
If the contact is broken during
OPENING
, the gate
stops and reverses after 3 sec.
•
If the contact is broken during
CLOSING
, the gate
keeps on working normally.
N.B.: Before wiring any SAFETY STRIP in
CLOSING, remove the jumper
between
terminal 23
and
terminal 24
.