JP6
FLASH
24V ac
JP8
M1
PED
J5
JP1
22
21
JP2
JP3
JP4
ST
AR
T
ST
OP
PED
JP5
RX -24V
TX - RX +24V
Test Photo
TX -24
FOT
O
FT
AP
JP9
F
N
4
JP7
JP1
= GREEN TERMINAL -Aerial connection
21
signal wire
22
earth wire
JP2
= RED WIRES - secondary MOLEX card 24V dc
JP3
= BLACK WIRES - primary MOLEX card 230V ac
JP4
= BLUE TERMINAL – command devices
1
START (N.O. contact)
2
STOP (N.C. contact)
3
PEDESTRIAN (N.O. contact)
4
NEUTRAL
JP5
= RED TERMINAL – line and photocells
5
photocell in closing (N.C. contact)
6
photocell in opening (N.C. contact)
7
RX photocells -24V
8
TX/RX +24V
9
TX photocells -24V
JP6
= YELLOW TERMINAL – flashing light
10
flashing light 24V ac - max 20W
11
flashing light 24V ac - max 20W
JP7
= BLACK TERMINAL – LIMIT SWITCH
12
neutral
13
limit switch in closing
14
limit switch in opening
JP8
= ORANGE TERMINAL - MOTOR
15
OPEN
16
NEUTRAL MOTOR OUTPUT
17
CLOSE
JP9
= GREEN TERMINAL - line 230V + earth
18
LINE
19
EARTH
20
NEUTRAL
Make sure a circuit breaker is properly fitted
to the gate electric box.
JP10
= GREEN TERMINAL – safety edge
23
safety edge in CLOSING
24
safety edge in CLOSING
J5
= input second radio channel jack
OP
EN
CL
O
SE
FC OPENING
FC CLOSING
NEUTR
AL