7
JP4
JP5
JP6
JP4
JP5
JP6
12Vdc
24Vdc
24Vca
12Vdc
24Vac
24Vdc
+A
C
+A
C
+AC -0AC
- 0
AC
- 0
AC
JP4
JP5
JP6
12Vdc
24Vac
24Vdc
+A
C
+A
C
+AC -0AC
12Vdc
24Vdc
24Vca
- 0
AC
- 0
AC
JP4
JP5
JP6
3.6 PHOTOCELLS
3.6.1 Photocells IN CLOSING
Feed the photocells through
7-8-9
, terminal
JP5
.
Wire the photocell contact (N.C. contact) to
5-7
, terminal
JP5
.
An additional photocell set can be wired in
SERIES
(N.C. contact).
-
If the photocell beam is broken during
CLOSING
,
the gate stops and reverses after 1,5 sec.
-
If the photocell beam is broken during
OPENING
,
the gate keeps on working normally.
The PHOTOCELLS IN CLOSING are important for
the safety of people and objects.
N.B.:
To desable the photocell in closing
during installation,
plug 5 and 9 together.
3.6.2 Photocells in OPENING
Feed the photocells through
7-8-9
, terminal JP5.
Wire the photocell contact (N.C. contact) to
6-7
, terminal
JP5
.
An additional photocell set can be wired in
SERIES
(N.C.
contact).
-
If the photocell beam is broken during OPENING, the gate
stops and reverses for 3 sec
The PHOTOCELLS IN OPENING are important for the safety of
people and objects..
N.B.:
Before wiring any PHOTOCELL in OPENING, remove the
jumper between
terminal 6
and
terminal 9.
EMERGENCY
STOP BUTTON
3.5
EMERGENCY STOP BUTTON
Wire the
STOP BUTTON
(N.C. contact) to
2-4
, terminal
JP4.
An additional STOP BUTTON contact can be wired in
SERIES
(N.C. contact)
The EMERGENCY STOP BUTTON is important for the safety
of people and objects
N.B.:
Before wiring any STOP contact remove the jumper between
terminal 2
and
terminal 4
.
PLUG 5 - 9