230V
6
3.3
START DEVICES
Wire the START contact (N.O. contact) to
1 – 4
, terminal
JP4
.
An additional
START
contact can be wired in
PARALLEL
(N.O. contact)
3.4
PEDESTRIAN OPENING
Wire the
PEDESTRIAN START
(N.O. contact) to
3-4
, terminal
JP4
.
An additional
PEDESTRIAN START
contact can be wired in PARALLEL
(N.O. contact).
OROLOGIO
3.3.2 KEY SWITCH
Wire the
KEY SWITCH
(N.O. contact) to
1-4
, terminal
JP4
.
3.2
MAIN POWER
The main line must be protected by a proper CIRCUIT BREAKER.
Connect the line 230V to
18-19-20
, terminal
JP9
, fulfilling the
polarity (18 PHASE – 19 EARTH – 20 NEUTRAL)
CIRCUIT
BREAKER
PHA
SE
NEUTR
AL
PEDESTRIAN
START
3.3.1 TIMER
It is possible to wire a
TIMER
(N.O. contact) to
1-4
, terminal JP4.
ATTENTION!:
when connecting a TIMER, the multi-users function
must be enabled. SW1 DIP 2 = ON