Irideon Control Installation and User Manual
53
Step 7:
Remove circuit board from chassis.
Step 8:
Remove display module ribbon cable from circuit board and
connect to new circuit board.
Step 9:
Install new circuit board and replace nine screws removed in
Step 6 above.
Step 10: Reconnect cables to P2, P3, P5, P6, P7, and P9. Use the
following table to assist in proper relocation of identified cables.
Step 11: Reconnect display module ribbon cable to LCD.
Step 12: Replace four screws in center front panel.
Step 13: Replace left and right front panels.
Connector
Cable Destination:
P2
Co24vdc to remote stations if present
P3
Connects data lines to and from remote stations if present
P5
Connects MCP to luminaire data run #1
P6
Connects power supply to circuit board
P7
Connects MCP to luminaire data run #2
P9
Auxiliary connection for future application
P1
REMOVE THESE
NINE SCREWS