Specifications and Reference
25
Specifications and Reference
For full product specifications, see the fos/4 Fresnel datasheet at
.
Environment
The fos/4 Fresnel operates in ambient temperatures of 0°C–40°C (32°F–104°F) and is rated IP20
(for use in dry locations only).
Fixture temperature information:
•
Maximum recommended ambient operating temperature: Ta=40°C (104°F)
•
Maximum anticipated external surface temperature: Tmax=80°C (176°F)
•
External temperature after 5 minutes of full-brightness operation at 25°C (77°F) ambient:
31°C (88°F)
•
External Temperature (steady state achieved) at 25°C (77°F): 41°C (106°F)
Dimensions and Weight
Model
Aperture Size
Array Type
Weight
fos4FL7
7 in (17.8 cm) Lustr X8
11.1 kg (24.5 lb)
fos4FD7
7 in (17.8 cm) Daylight HDR 11.1 kg (24.5 lb)
Electrical
•
Operates between 100 VAC and 240 VAC at a frequency of 50/60 Hz.
•
Requires power from a non-dimmable source.
•
When not connected to AC power, the fixture can be powered by an external battery with
a range of 24–36 VDC.
•
Link up to 6 additional fixtures (12 A max) via Power Thru connector when using an R20
Relay Module (consult breaker-trip curves when using other equipment).
Fixture
Maximum Power Consumption
Inrush (120 V)
Inrush (240 V)
FL7 and FD7
270 W
46.6 A
110.2 A
Typical Power Consumption
100 V
120 V
230 V
FL7
Idle Power/Current
7.5 W
0.10 A
8.8 W
0.11 A
8 W
0.09 A
Direct at Full/Current
179.4 W
1.83 A
177.7 W
1.51 A
172.9 W
0.79 A
FD7
Idle Power/Current
7.5 W
0.10 A
7.7 W
0.11 A
7.6 W
0.09 A
Direct at Full/Current
218.3 W
2.23 A
219.8 W
1.87 A
219.9 W
0.99 A