Mobil-PDi/MDi remote control
Doc. no. MA007828_00
21 / 34
EN
But-
ton
Normal mode Simple programming mode
for programs 1-4
Enhanced programming
mode for program 5
–
Current Lux value as
switching threshold
Current Lux value as
switching threshold
–
Switching threshold 100
Lux
Switching threshold
100 Lux
–
Switching threshold 250
Lux
Switching threshold
250 Lux
–
Switching threshold 400
Lux
Switching threshold
400 Lux
–
Switching threshold 600
Lux
Switching threshold
600 Lux
–
Switching threshold 800
Lux
Switching threshold
800 Lux
–
Switching threshold
2000 Lux
Switching threshold
2000 Lux
–
Switching between fully
automatic/semi-automat-
ic
LED confirmations:
Fully automatic: red LED
flashes
Semi-automatic: blue
LED flashes
Switching between fully
automatic/semi-automat-
ic
LED confirmations:
Fully automatic: red LED
flashes
Semi-automatic: blue
LED flashes
–
Pulse operation: Pulse 1
second.
Pauses after pulse can
be switched through in a
cycle:
9 (factory setting)/ 30/60
sec./for future functions
Pulse operation: Pulse 1
second.
Pauses after pulse can
be switched through in a
cycle:
9 (factory setting)/ 30/60
sec./for future functions
–
Channel 1 switch-off
delay time:
1 minutes
Channel 1 switch-off
delay time:
1 minutes
–
Channel 1 switch-off
delay time:
2 minutes
Channel 1 switch-off
delay time:
2 minutes