Mobil-PDi/MDi remote control
Doc. no. MA007828_00
25 / 34
EN
To activate and deactivate advanced programming mode:
1. Press the
button twice to activate advanced programming mode.
The light blue LED is lit.
The detector is in advanced programming mode.
2. Press the
button twice to exit advanced programming mode.
The light blue LED goes out.
The detector reverts to normal operation.
If you do not press the
button, advanced programming mode
exits automatically after 5 minutes.
The following table shows which button is responsible for which commands
in simple and advanced programming mode.
7.3.1 Functions of buttons in programming mode
But-
ton
Simple programming mode for
programs 1-4
Enhanced programming mode for
program 5
Channel 1: Switch between on/
off in initialization phase
–
Switching threshold 10 lux
Switching threshold 10 lux
Exit programming mode
Exit advanced programming
mode
Start advanced programming
mode
–
Current Lux value as switching
threshold
Current Lux value as switching
threshold
Switching threshold 100 Lux
Switching threshold 100 Lux
Switching threshold 250 Lux
Switching threshold 250 Lux
Switching threshold 400 Lux
Switching threshold 400 Lux
Switching threshold 600 Lux
Switching threshold 600 Lux
Switching threshold 800 Lux
Switching threshold 800 Lux
Switching threshold 2000 Lux
Switching threshold 2000 Lux
Enhanced pro-
gramming mode for
program 5