background image

20

Symbol „Conflict of Address“   (see chapter 11.9.1)
Symbol „Loco is blocked“  

(see chapter 11.9.2)

Symbol „Shuttle Train Mode“   (see chapter 17)
Symbol „Consist“ 

  

(see chapter 12)

11.4. Deleting a locomotive

You can delete any loco at any time should you not need them 

any more. First select the loco and assign it to a throttle.

• Select  the  loco  menue  of  the  appropriate  throttle  and  select 

„Delete Loco” in the menue. Then another menue opens.

• Select „Delete” and the loco will be deleted.

11.5. Multi cab display

If  you  wish  you  can  run  up  to  5  locomotives  with  each  cab 

simply touch the appropriate screen button in order to toggle 

between these 5 locomotives.

• Make sure the command station is in train control mode.
• Call up the multi cab window by touching the input field below 

the speedometer.

a)  Currently active locomotive controlled by this cab. (You can 

recognise it by its open frame).

b)  Function button symbols of the currently active locomoti-

ve.

Figure 50

e)

b)

c)

a)

d)

Run locomotives

Figure 48

b)

a)

c)

Figure 49

Active loco: this loco is running

Loco is blocked: this loc is run from another throttle
You can now navigate the list either with the joystick or with 

the  stylus  until  you  have  found  the  desired  loco.  Alternately 

you can type in the loco address. ECoS scrolls automatically to 

the corresponding address within the list. After confirming the 

loco it will be called up by a throttle.

11.2.1. Swapping the cabs

Touch  this  symbol  for  swapping  the  currently  active  locomo-

tives: the left locomotive will be handed over to the right cab 

and vice versa.

11.2.2. Clearing a cab

Sometimes one does not want to have any locomotive assig-

ned to a cab. Of course this is also possible.

• Call  up  the  locomotive  menu  of  the  cab  which  you  want  to 

clear.

• Select “Clear cab”.

11.3. Speedometer display options

After selection the loco speed is displayed on the speedometer. 

Besides the information mentioned in chapter 6.3 the speedo-

meter shows further important data.
a)  Data protocol of loco
b)  Address of loco
c)  Current speed step resp. speed of locomotive

Subject to the status of the loco the following symbols can be 

displayed:

Figure 47

• Type in the address using the number block.
• Confirm your selection

If there is no other loco with the same address registered ECoS 

will automatically enter the necessary data in the background 

with  the  given  address  and  the  name  „New>xxxx<”  and  by 

setting the Motorola®28-protocol.
Which  protocol  ECoS  should  use  whenever  you  enter  a  loco 

directly can be pre-set in the menue. You find details in chapter 

21.5.1.

11.2. Call up a locomotive with the cab

You can either assign one locomotive each to each cab or work 

with the multi cab display. 
Press the locomotive-screen button of the desired cab. Alterna-

tely you may also press the locomotive selection button. 
A list containing all registered locomotives will open:

a)  Locomotive is run by the other cab; therefore it cannot be 

operated with this cab

b)  Marked locomotive
c)  Locomotive adddress (in case of M4 locomotives “M4“ will 

be displayed)

d)  Data format of the locomotive (empty in case of M4 loco-

motives)

e)  Sort locomotive list by name
f)  Sort locomotive list by address
g)  Sort locomotive list by active locomotives
h)  Sort locomotive list by going through locomotive list 1, 2 or 3
i)  Sort  locomotive  list  by  type  of  locomotive  (steam,  diesel, 

electric)

k)  Select marked locomotive
l)  Cancel without selecting a locomotive
m) One element down
n)  Move list downwards
o)  Move list upwards
p)  One element up
q)  Number field for numeric selection
You can fade in additional pictograms for each loco:

Figure 46

b)

i)

n)

k)

f)

e)

h)

g)

q)

l)

p)

m)

o)

c)

d)

a)

Summary of Contents for ECoS 50200

Page 1: ...1 User Manual For ECoS with coloured display firmware 3 1 x First edition February 2010 ECoS E S U C O M M A N D S T A T I O N ESU P N 00810 08526...

Page 2: ...1 Run locomotives 17 11 1 Adding new locomotives 17 11 1 1 Entering M4 locomotives 17 11 1 1 1 Hints for save registration of mfx locos 17 11 1 1 2 New registration of M4 locomotives 17 11 1 2 Enterin...

Page 3: ...M 30 18 2 Introduction to Motorola programming 30 18 3 Overview of programming options 30 18 4 Manual programming DCC 30 18 4 1 Read CVs 30 18 4 2 Write CVs 30 18 4 3 Programming on the Main POM 31 18...

Page 4: ...ECoS is switched off Do not attempt to open ECoS Inappropriate handling may lead to damage of the command station 3 1 What does M4 mean At some points in this catalog you will notice the term M4 for...

Page 5: ...om transport damage Pack your ECoS into the blister and both cartons prior to dispatch by mail or parcel service 5 2 Locating the device Place ECoS on a flat clean and dry surface within sight of your...

Page 6: ...ect pola rity B 0 otherwise many older locomotives and acces sories e g k83 k84 may not function properly Figure 4 B 0 To the power supply B 0 2 digit track 3 digit track 6 3 Overview of control input...

Page 7: ...ction will be triggered Examples for screen buttons Touching this screen button confirms an action Touching this screen button cancels an action any data ente red during this particular process will n...

Page 8: ...you notice that functions are only activated at every second speed step then your decoder does not support the 27 speed steps Please switch to Motorola14 ESU extended all decoders to suit the Motorol...

Page 9: ...unctions will be signalled to all locos in the consist Locos of a consist can be called up on another throttle but they cannot actually be run with that throttle 7 3 Running shuttle trains Many model...

Page 10: ...shuttle train operations The s88 bus consists of up to 32 s88 modules that can process either 8 or 16 feedback signals each These modules are wired in a chain bus s88 modules are available from variou...

Page 11: ...e voltage with the aid of a screw driver Left hand limit ca 14 5V Right hand limit ca 21 5V 8 2 2 Practical voltage settings We recommend the following settings for the different scales N gauge 15V 16...

Page 12: ...distribution module Either the ESU ECoSlink Terminal or the terminal box by M rklin is sui table You will find more details in chapter 20 8 6 Computer interface Each ECoS has an 8 way RJ45 network soc...

Page 13: ...ince most commercially available boosters have problems with the Selectrix data packet no Selectrix data are supplied to the external booster interface Therefore it is not possible to run Selectrix lo...

Page 14: ...odules are linked on the track terminals This is necessary in order to operate the s88 modules ECoS was tested with the following s88 modules M rklin 6088 LDT RM DEC 88 LDT RM GB 8 Viessmann 5217 Befo...

Page 15: ...ng it to the left you can cancel the selection In fact you can move up and down in any menu by moving the joystick Moving it to the right or pressing it down selects an element moving it to the left e...

Page 16: ...up wards Reduces the current value alternatively move joystick down wards 10 8 Radio buttons and choice fields Radio buttons enable you to make a choice out of a group of possibilities Only one entry...

Page 17: ...vailable After pressing the Go button all M4 locomotives will register anew in order to assure data veri fication between decoders and command station 11 1 2 Entering M rklin locomotives into the data...

Page 18: ...dress Here you enter the current address of the loco The accepted address range is subject to the data format and may be restric ted The locomotive is actually operated with this address at the track...

Page 19: ...e the loco on the programming track Select the option Programming on programming track Fig 44 Push the programming icon ECoS will now program the fol lowing parameters The address in CV1 resp CV 17 18...

Page 20: ...of the cab which you want to clear Select Clear cab 11 3 Speedometer display options After selection the loco speed is displayed on the speedometer Besides the information mentioned in chapter 6 3 the...

Page 21: ...the address 03 The differing data for mat does not have any impact because ECoS cannot know if a modern multi protocol decoder e g LokSound will respond to both formats In practice assigning the same...

Page 22: ...You can delete a consist just as easily as with individual locos refer to chapter 11 4 Any locos that were part of the deleted consist will of course not be deleted as well They remain as individual l...

Page 23: ...l mode by clicking onto this sym bol in the main menu line a Choice buttons for the desired turnout control panel b Choice buttons for displaying the following 15 pages c Panel displaying 2 x 8 access...

Page 24: ...table A grey frame will appear Touch the panel at the location where the turntable should be displayed Then the configuration dialogue for new turntables will open 14 2 1 Type of turntable Here you ca...

Page 25: ...tep buttons or Pressing the Clear button will save the new position as track number 1 and simultaneously delete the pre vious track number 1 After that all other tracks will be entered in any sequence...

Page 26: ...ssories with particularly high current draw are part of the route They high current could lead to a voltage drop and the pause between commands assures reliable operation 15 1 1 3 Trigger a route with...

Page 27: ...aphically You can switch any turnouts or signals simply by touching the appro priate symbol 16 1 Configuring the track diagram First call up the track diagram a Area for placing track diagram elements...

Page 28: ...ely stops in station 2 You may have to experiment a little Once the pre set layover time is past T1 the timer gives the signal and the train receives a command to change direction The train is still s...

Page 29: ...Mode Now the loco can be controlled manually Figure 82 18 Programming Decoders By programming we mean the method of electronically chan ging certain parameters of decoders This applies to all types o...

Page 30: ...ndards from 0 to 7 Push the screen button f Write CV If successful the word OK will be displayed after as short while in field b If not successful then Error or No Loco will be displayed No Loco means...

Page 31: ...rs their value ranges and their purpose as well as the layout of the elements on the ECoS monitor are summarised here Every decoder that has a graphic profile can be programmed by this method The ECoS...

Page 32: ...Hp1 or Hp0 of the corresponding main signal If the distant si Programming Decoders gnal is linked to a two aspect main signal then press HP1 or Hp0 once again after the distant signal has started agai...

Page 33: ...signals to the old system If you for in stance run a loco with your old system on speed step 10 and subsequently reduce this to speed step 2 with one of the two cabs on ECoS the old system will still...

Page 34: ...circuit Thus you can set the system so that the internal booster will only be switched off if a short circuit occurs in its own district The Go button blinks green if at least one booster district is...

Page 35: ...switches off if a short circuit occurs in its own district 21 2 2 ECoSBoost configuration For each ECoSBoost booster connected you can set the current threshold individually Simply choose the desired...

Page 36: ...This affects the integral stop button as well as any other stop buttons of external devices connected to ECoSlink and ECoSniffer Lock entering deleting and editing objects prevents any en tering delet...

Page 37: ...ting the touch screen In some rare cases due to electrical or mechanical fatigue it may happen that the touch sensitive screen must be calibrated again You can start this process at any time Press the...

Page 38: ...dows If you use a static IP address and your PC is already configured you do not have to change anything in your PC Continue rea ding in chapter 24 1 2 If you use a PC that has not been connected to a...

Page 39: ...gure will be nee ded for the next step 24 2 Web interface To establish a connection with ECoS start your Internet brow ser Type in the upper command line http IP Adresse IP Address means in this case...

Page 40: ...n from the mains Press the function buttons F2 and F7 of the left cab simultane ously and hold them down Switch on your command station Make sure that you remove the batteries from your command statio...

Page 41: ...buttons during the start up of your command station screen as per figure 121 will open 25 2 Execute a factory reset In many cases technical problems with the software are not actually caused by the in...

Page 42: ...tion offer When registering you enter the serial number of your ECoS Thus your ECoS is automatically registered with ESU Should there be any software or other problems we can then inform you directly...

Page 43: ...e established the following amounts for the ECoS Type of fault P r i c e in Replacement of display touch pad and backlight 99 50 Repair of the track output or programming output 72 50 Replacing a defe...

Page 44: ...44 Notes...

Page 45: ...ded the failure is demonstrably due to faulty design manufacturing material or transport Any further claims are explicitly excluded The warranty expires 1 In case of wear and tear due to normal use 2...

Page 46: ...er throttles with dedicated end position and locomotive choice button 2 x Two way analogue joysticks 2 x 9 function buttons as well as Stop and Go button 3 Sockets for ECoSlink devices Socket for ECoS...

Page 47: ...ders The table contains the link between the status of the DIP switches and the turnout address as well as to the M rklin keyboards Keyboard number K e y b o a rd Button Turnout address Turnout decode...

Page 48: ...48 ESU P N 00810 08526 2010 by ESU electronic solutions ulm GmbH Co KG...

Reviews: