12
8. POSSIBLE FAULTS, CAUSES AND SOLUTIONS
1)
The motor does not start.
2)
Motor operates but there is no pressure.
3)
Motor over-heating.
4)
Pump does not deliver rated capacity.
5)
Motor starts and stops automatically.
6)
Shaft rotates with difficulty.
9. TECHNICAL DATA
Liquid temperature: ......................... 4ºC - 40ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
Ambient relative humidity, max.: ............... 95%
Motor class
I
.
Other data see Figure 2.
1
2
3
4
5
6
POSSIBLE PROBLEM
SOLUTIONS
X
X
Pump blocked
Disconnect it and take it to the official Technical
Service
X
Foot valve clogged
Clean it or replaced by new one
X
X
Total head higher than expected
Verify geometric head and loss of head
X
X
X
Wrong tension
Check that the tension is the same as that on the
name plate
X
X
Water level in well or tank has come
down
Verify suction head
X
Fuse or thermal relay disconnected
Change fuse or thermal relay
X
X
Impellers are worn out
Disconnect pump and take it to your Service
Dealer
X
Foot valve not submerged
Be sure suction pipe is submerged
X
Pump was not primed
Fill pump body with water
X
X
Room not properly aired
Provide good ventilation
X
Air entry
Seal unions and joints properly
Summary of Contents for Max series
Page 2: ......
Page 33: ...RU 33 5 A B C 3 D 0 03 E F G H I 8 J K L...
Page 36: ...ZH 36 5 A B C 3mm D 0 03A E F G H I 8 J K L...
Page 38: ...ZH 38 3 5 4 5 www espa com 6 1 2 3 4 5 P2 6 EC 7 8 9 10 11 12 MEI 13 14 15...
Page 40: ...AR 40...
Page 41: ...AR 41...
Page 42: ...42...
Page 44: ...44 Fig 2 Abb 2 Afb 2 2 2 2...
Page 45: ...45 Fig 3 Abb 3 Afb 3 P c 3 3 3 Fig 4 Abb 4 Afb 4 P c 4 4 4...
Page 46: ...46 Fig 5 Abb 5 Afb 5 5 5 5 A B C D E F G H I J K L...
Page 47: ...48...
Page 48: ...C d 2258 03 2020 08 47...