3.4. Electrical connection

 

The  electrical  installation  must  have  a  multi-
pole  isolator  with  minimum  3  mm  contact 
openings,  The  protection  of  the  system  will 
be 

based 

on 

differential 

switch 

(Δfn = 30 mA) 

The  power  cable  must  correspond  at  least  to  the 
type  H05  RN-F  (according  to  60245  IEC  57)  and 
having terminals. 

The  connection  and  its  dimensioning  must  be  per-
formed  by  a  qualified  installer  according  to  the 
needs of the facility and following the regulations in 
force in each country. 

The motors are not thermally protected. They 
must  be  connected  to  a  motor-protective 

circuit breaker that can be adjusted manually. 
Set  the  circuit  breaker  according  to  the 
current given in the rating plate plus 10%. 

Follow instructions given on fig.1 for correct electri-
cal connection. 

3.5. Pre-start checks

 

Ensure  the  voltage  and  frequency  of  the 
supply  corresponds  to  the  values  indicated 
on the electrical data label.

 

Ensure that the pump shaft is rotating freely.

 

Fill  the  pump  body  with  water  through  the  self-
priming  plug  opening.  If  a  foot  valve  has  been 
installed, also fill the suction pipe.

 

Check all joints and connections for leaks. 

THIS PUMP MUST NEVER BE DRY RUN. 

4. STARTING

 

Ensure all valves in the pipework are open.

 

Connect power supply. There will be a delay before 
water appears at the end of the discharge pipe.

 

Viewings from the fan ensure that the rotation of the 
motor  is  clockwise.  On  three  phase  pumps  the 
motor may rotate anticlockwise. If this is happening, 
the flow  will  be  lower than  expected. To rectify this 
situation  the  two  supply  phases  need  to  be  re-
versed.

 

Ensure  that  the  absorbed  current  is  the  same  or 
lower  than  the  maximum  shown  on  the  nameplate. 
Adjust the thermal relay if is necessary.

 

If  the  pump  fails  to  operate  refer  to  the  possible 
faults, causes and solutions list for assistance.

 

5. MAINTENANCE

 

Under  normal  conditions  these  pumps  require  no 
special or planned maintenance. 

Clean  the  pump  with  a  damp  cloth  without  using 
harsh products. 

If  the  pump  is  not  to  be  operated  for  a  long 
period  it  is  recommended  to  remove  it  from 
the installation, drain down and store in a dry, 
well ventilated place.

 

ATTENTION:  In  the  event  of  faults  or 
damage  occurring  to  the  pump,  repairs 
should  only  be  carried  out  by  an  authorised 
service agent.

 

The 

Official 

Technical 

Services 

list 

is 

in 

www.espa.com

. 

6. DISPOSING OF THE PRODUCT

 

When  the  pump  is  eventually  disposed  of,  please 
note  that  it  contains  no  toxic  or  polluting  material. 
All main components are material identified to allow 
selective disposal.

 

This product or parts of it must be disposed of in an 
environmentally  sound  way,  use  the  waste 
collection service. If this is not possible, contact the 
nearest ESPA service workshop.

 

7

PLATE SHOWING CHARACTERISTICS

 

 

 

DESCRIPTION 

Item reference

 

V fre item specifications

 

Flow 

Minimum working pressure 

Motor max. nominal output (P2) and frequency

 

EC mark 

Pressure 

Maximum pressure

 

Year and week of manuf Pump serial number

 

10 

Max. liquid temperature

 

11 

Engine rotation speed 

12 

Minimum Efficiency Index

 

13 

Designated motor insulation

 

14 

Continuous operation symbol

 

15 

Name and address of vendor responsible for the product 

 

 

 

 

Summary of Contents for Max series

Page 1: ...Spanish 9 FR Manuel d instructions Traduction de l original en espagnol 13 DE Gebrauchsanweisung bersetzungausdem Original in Spanisch 17 IT Manuale d istruzioni Traduzione dall originale spagnolo 21...

Page 2: ......

Page 3: ...30 UE Norme EN 61000 6 1 et EN 61000 6 3 Directive Basse Tension 2014 35 UE Norme EN 60335 1 et EN 60335 2 41 Directive 2009 125 CE co conception R glement UE 2019 1781 moteurs lectriques et aux varia...

Page 4: ...tr nicos Diretiva 2011 65 UE RoHS II Norma EN 50581 NL VERKLARING VAN OVEREENSTEMMING Wij verklaren onder onze verantwoordelijkheid dat de producten in deze handleiding voldoen aan de volgende EU rich...

Page 5: ...en la placa G Recuerde cebar la bomba H Aseg rese que el motor pueda autoventilarse I Este aparato pueden utilizarlo ni os con edad de 8 a os y superior y personas con capacidades f sicas sensoriales...

Page 6: ...e la bomba y consecuencias de todo tipo acerca de las cuales declinamos cualquier responsabilidad ndice de eficiencia m nima En aplicaci n del reglamento europeo 547 2012 el ndice de eficiencia m nima...

Page 7: ...EN MARCHA Abra todas las v lvulas de paso en las tuber as tanto en la aspiraci n como en la impulsi n Conecte el interruptor de suministro El agua puede tardar unos segundos en recorrer toda la longi...

Page 8: ...ra ambiente 0 C 40 C Temperatura de almacenamiento 10 C 50 C Humedad relativa ambiente m xima 95 Motor clase I Otros datos v ase figura 2 1 2 3 4 5 6 CAUSAS SOLUCIONES X X Bomba bloqueada Desmontarla...

Page 9: ...indicated on the name plate G Remember to prime pump H Check for motor self ventilation I This apparatus may be used by children 8 years or older and persons with reduced physical sensory or mental c...

Page 10: ...the minimum efficiency index after 01 01 2015 must be MEI 0 40 The reference value for the most efficient hydraulic pumps is rated at MEI 0 70 The performance curves and efficiency characteristics ca...

Page 11: ...be lower than expected To rectify this situation the two supply phases need to be re versed Ensure that the absorbed current is the same or lower than the maximum shown on the nameplate Adjust the the...

Page 12: ...onnect it and take it to the official Technical Service X Foot valve clogged Clean it or replaced by new one X X Total head higher than expected Verify geometric head and loss of head X X X Wrong tens...

Page 13: ...e pas oublier d amorcer la pompe H Contr ler que le moteur peut s autoventiler I Cet appareil peut tre utilis par des enfants de 8 ans et plus ainsi que des personnes aux capacit s physiques sensoriel...

Page 14: ...s toute responsabilit Indice de rendement minimal En application du r glement europ en 547 2012 compter du 1er janvier 2015 l indice de rendement minimal doit tre MEI 0 40 La valeur de r f rence corre...

Page 15: ...as es le sens de rotation du moteur peut tre inverse Dans ce cas le d bit peut tre inf rieur l esp r et il faut invertir deux phases de l alimentation de le tableau de connexions V rifiez que le coura...

Page 16: ...z si la tension correspond celle indiqu e sur la plaque signal tique X X Abaissement du niveau de l eau au puits R glez la hauteur d aspiration X Fusible ou thermique d branch s Remplacez le fusible o...

Page 17: ...daran die Pumpe anzuf llen H Achten Sie auf die Eigenbel ftung des Motors I Dieses Ger t kann von Kindern ab 8 Jahren und Personen mit eingeschr nkten k rperlichen sensorischen oder mentalen F higkeit...

Page 18: ...Ma nahmen Mindesteffizienzindex Gem Verordnung 547 2012 muss der Mindesteffizienzindex ab dem 01 01 2015 mindestens MEI 0 40 betragen Der Referenzwert f r hydraulische Pumpen mit dem h chsten Wirkung...

Page 19: ...ckg ngig gemacht werden berpr fen Sie dass der Eingangsstrom gleich oder kleiner als die maximale auf dem Etikett angegeben ist Zur cksetzen des thermischen Relais wenn n tig Wenn die Pumpe nicht refe...

Page 20: ...schild angegebenen Pumpenspannung vergleichen X X Wasserstand im Brunnen f llt Saugh he entsprechend einstellen X Sicherung bzw Thermoschutzrelais abgeschaltet Sicherung bzw Thermoschutzrelais austaus...

Page 21: ...atevi di adescare la pompa H Assicuratevi che il motore possa autoventilarsi I Questo apparecchio pu essere utilizzato da bambini di et non inferiore agli 8 anni e da persone inesperte impreparate o c...

Page 22: ...ristiche tecniche riduzione della vita utile della pompa e altri inconvenienti di ogni tipo per i quali decliniamo qualsiasi responsabilit Indice di efficienza minima In applicazione del regolamento e...

Page 23: ...RE A SECCO 4 MESSA IN MARCIA Aprire tutte le valvole a saracinesca che esistano nei circuiti d aspirazione e d impulsione Collegare la spina alla rete elettrica L acqua pu impiegare alcuni secondi a p...

Page 24: ...la e rivolgersi al Servizio Tecnico Ufficiale X Valvola di fondo ostruita Pulirla o sostituirla con un altra X X Altezza manometrica totale superiore a quella prevista Regolare l altezza geometrica e...

Page 25: ...H Verifiquem que no motor possa funcionar a ventila o autom tica I Este aparelho pode ser utilizado por crian as com idade igual ou superior a 8 anos bem como por pessoas com capacidades f sicas senso...

Page 26: ...o do tempo de vida til da bomba e consequ ncias de todo o tipo sobre as quais o fabricante declina toda e qualquer responsabilidade ndice de efici ncia m nima Em conformidade com o regulamento europeu...

Page 27: ...ou uni o com fugas A BOMBA NUNCA DEVE FUNCIONAR EM SECO 4 ARRANQUE Abra todas as v lvulas de seccionamento que existam nos circuitos de aspira o e compress o Ligar a ficha rede A gua poder demorar alg...

Page 28: ...X X Bomba bloqueada Desmontar e levar a um servi o t cnico oficial X V lvula de p obturada Limpar ou substituir a v lvula X X Altura manom trica total superior prevista Comprovar a altura geom trica e...

Page 29: ...niet de pomp te vullen H Zorg dat de motor zichzelf kan koelen I Dit apparaat mag worden gebruikt door kinderen van acht jaar en ouder en door personen met lichamelijke zintuiglijke of geestelijke bep...

Page 30: ...e motor een verlies van de technische capaciteiten een vermindering van de levensduur van de pomp en allerlei gevolgen waarvoor we de ansprakelijkheid van de hand wijzen Minimale effici ntie index Ove...

Page 31: ...BEDRIJFSTELLING Open alle afsluiters in zowel de aanzuig als de persleiding Zet de spanningsvoorziening aan Het kan enkele seconden duren voordat het water over de hele lengte van de leiding stroomt C...

Page 32: ...wen en naar een Erkende Technische Dienst brengen X Voetventiel verstopt Schoonmaken of door nieuwe vervangen X X Totale transporthoogte groter dan voorzien Controleer de geometrische hoogte en de dru...

Page 33: ...RU 33 5 A B C 3 D 0 03 E F G H I 8 J K L...

Page 34: ...RU 34 34 1 34 2 34 2 1 34 2 2 34 2 3 34 3 35 4 35 5 35 6 35 7 35 8 42 9 43 10 44 1 40 2 4 2 1 7 50 3 2 2 fn 30m 1 2 3...

Page 35: ...RU 35 3 4 6 4 C 40 C 0 C 40 C 10 C 50 C 95 I 2 5 1 2 3 4 5 P2 6 CE 7 8 9 10 11 12 MEI 13 14 15 7 1 2 3 4 5 6 1 2 3 4 5 6 X X X X X X X X X X X X X X X X X X...

Page 36: ...ZH 36 5 A B C 3mm D 0 03A E F G H I 8 J K L...

Page 37: ...ZH 37 37 1 37 2 37 3 37 3 1 37 3 2 38 3 3 38 3 4 38 3 5 38 4 38 5 38 6 38 7 39 8 39 9 42 10 43 11 44 1 40 C 2 3 4 3 1 8mm 10mm 3 2 7 50 3 3 3 3 4 3 fn 30 mA H05 RN F IEC6024557 10 1...

Page 38: ...ZH 38 3 5 4 5 www espa com 6 1 2 3 4 5 P2 6 EC 7 8 9 10 11 12 MEI 13 14 15...

Page 39: ...ZH 39 7 1 2 3 4 5 6 8 4 C 40 C 0 C 40 C 10 C 50 C 95 I 1 2 3 4 5 6 X X X X X X X X X X X X X X X X X X...

Page 40: ...AR 40...

Page 41: ...AR 41...

Page 42: ...42...

Page 43: ...SATOR 5 L NEA 6 AZUL RED WHITE BLACK CAPACITOR LINE BLUE ROUGE BLANC NOIR CONDENSATEUR TENSION BLEU ROT WEISS SCHWARZ KONDENSATOR SPENNUNG BLAU ROSSO BIANCO NERO CONDENSATORE LINEA BLU VERMELHO BRANCO...

Page 44: ...44 Fig 2 Abb 2 Afb 2 2 2 2...

Page 45: ...45 Fig 3 Abb 3 Afb 3 P c 3 3 3 Fig 4 Abb 4 Afb 4 P c 4 4 4...

Page 46: ...46 Fig 5 Abb 5 Afb 5 5 5 5 A B C D E F G H I J K L...

Page 47: ...48...

Page 48: ...C d 2258 03 2020 08 47...

Reviews: