background image

The  recorder  has  been  designed  for  use  in  the
driver's  cab.  The  kit  includes  a  car  holder  for
mounting  on  the  front  or  side  window  of  the  car.
When mounting the bracket, select the appropriate
mounting location, following the instructions below:

Dispose  of  the  product  at  the  end  of  its  operation  in  accordance  with  applicable  legal
regulations. In accordance with European Directive 2002/96/WE and the 

Act  on  Waste

Electrical and Electronic Equipment, this label indicates the ban on the placement of used
electronic equipment together with other household waste. Return the worn device to the
appropriate storage point, or send it to us, because dangerous components in the device
may be a threat to the environment.
Batteries  and  accumulators  containing  harmful  substances.  Used  batteries  and
accumulators can be taken away free of charge to the appropriate storage point, to us or
wherever batteries and accumulators are sold.
Thanks  to  this,  you  meet  legal  requirements  and  contribute  to  the  protection  of  the
environment!

ASSEMBLY:
Press the suction cup (A) in the designated area, to the front or side window of the car, making
sure that the suction cup and glass are clean, without any traces of water or other contaminants.
Then move the locking lever (B) towards the glass.
After mounting the bracket on the glass, unlock the lower support (C) and place the recorder
between the two jaws (D) of the bracket. Then snap the DR­203 with the jaws so that it is rigidly
placed and that it does not slide out while driving. Use the two knobs to adjust the viewing angle,
position and direction of the recorder display.

­ do not cover the driver's field of vision
­ do not mount the set within the range of the

operation of the airbags

­ do not attach the set too close or opposite the

head so that it doesn't pose a threat during a
road incident

C

B

D

D

E

A

Turn the knobs so that the handle doesn't unlock and doesn't move while driving. After 

some

time of use, re­tighten the knobs and tighten the clamping jaws and make sure that the recorder
is properly  mounted.
At  any  time,  the  recorder  can  be  removed  from  the  holder  by  releasing  the  (E)  unlocking

button.

6

Summary of Contents for DR-203

Page 1: ...ace MaR Registr tory a dataloggery uv d www emareg cz shop emareg cz Pro technickou pomoc a dotazy n s kontaktujte 420 777884900 info emareg cz Registr tor teploty s tisk rnou bezdr tov p enos mezi id...

Page 2: ...perate can be signaled and recorded Sensors are designed to work in hard environmental conditions low temperatures high humidity with IP 65 protection Cable probes with stainless steel measuring tips...

Page 3: ...eration with a smartphone Bluetooth sending data to the server SMS notification PDF reports by e mail GPS location automatic change of summer time time zones temperature and door opening alarms sound...

Page 4: ...draws energy even when there is no device connected to it When not in use disconnect it to avoid discharging the battery A lithium ion battery was used to power the recorder The battery can not be dam...

Page 5: ...ile devices Free application for mobile devices allows for easy operation of the device from the smartphone screen The application allows you to monitor temperature signal alarms implement courses sen...

Page 6: ...and contribute to the protection of the environment ASSEMBLY Press the suction cup A in the designated area to the front or side window of the car making sure that the suction cup and glass are clean...

Page 7: ...of the battery recorder should last for a minimum of 3 hours The battery symbol informs about the state of charge of the recorder The device should not be completely discharged and the battery life ma...

Page 8: ...COM green radio communication BAT red low battery SIGNALING OF DIODES every60sec blinksonce communicationOK every 60 sec blinks twice communicationlost blinksonceatstartup afterinsertingthebattery eve...

Page 9: ...housing through a cable gland measuring tips of additional cable probes are made of stainless steel and allow direct contact with food the standard range of wireless sensors in open terrain is 100m W...

Page 10: ...compartment with space for thermal paper 2 micro USB port for data transfer 3 power socket 4 Service socket not used 5 The kit includes a roll of thermal paper that must be installed in the printer T...

Page 11: ...s the course is on current time temperature unit After completing the recorder installation the device must be configured The parameters menu is divided into two groups basic menu for the driver advan...

Page 12: ...to set a time earlier than the current one When the recorder has stored data in the memory the change of back date is blocked to prevent overwriting and loss of data First archive the data via USB or...

Page 13: ...ons and Auto OFF YES after turning off the recorder the sensors go into sleep mode and they do not save the data Auto OFF NO after turning off the recorder the sensors are still saving data in their c...

Page 14: ...intout under the place for a signature in which you can place additional user information e g Driver s first and last name advertising slogan or carrier s website adress Maximum 4 lines of text 19 cha...

Page 15: ...to cancel process press button After pressing the process of data removal will start Data will be lost irrevocably Data security before any change to the parameters in the service menu please make a...

Page 16: ...the recorder will display a list of all available sensors Example on the left Check the sensor s number and choose the one you want to add by pressing If it is wireless sensor with data stored in the...

Page 17: ...alue range 10 0 10 0 C minimal temperature level If the temperature reaches this level the recorder will activate buzz alarm and an alarm will be displayed Alarms will be saved in the memory and marke...

Page 18: ...OK The list of connected sensors will appear Chose a sensor to delete using OK Amessage will appear Confirm using OK or cancel deleting using menu button After removing the sensor you will be moved ba...

Page 19: ...ting window will appear as on the left Choose option Historical report and press OK If the message no data appears this means there is no data of the chosen time in the memory To cancel the printing p...

Page 20: ...4 D1234 drzwi otwarte Raport z dostawy DR 203 v 1 Numer fabryczny 20180511 www esco eu com R 00023 2018 08 22 23 31 Czas T1 C T2 T3 T4 D1234 C C C 2018 08 22 Podpis Za adunek 21 59 Roz adunek 08 00 1...

Page 21: ...ntout To register the start of delivery press button Icon will appear and message will be displayed To register the end of the delivery press Icon will go out and message will be displayed While recor...

Page 22: ...settings of the type of door opening circuit NO NC are in the service menu see 10 4 While opening the door connectors of limit sensor are opening or closing and they pass a signal of changing the posi...

Page 23: ...he recorder and connect to a USB port on your computer Open the disk in Windows Explorer On the USB disk will be created the main DR 203 folder in which they will be created subfolders with individual...

Reviews: