background image

The DR­203 recorder is designed to monitor temperature, during transport of goods and their storage
in truck or car refrigerators, cold chain and product stores. The thermograph has been designed and
manufactured in accordance with the applicable European standards for the transport and storage of
food  products.  Thanks  to  it,  food  companies  and  carriers  can  monitor,  archive  and  document  the
temperature at every stage of the food supply and storage chain. The device meets the requirements
of
the European Union Directive 92/1/EWG and the European Commission Regulation no. 37/2005. The
recorder also meets the standards PN­EN 12830:2002 and PN­EN 13485:2002. The set includes a
manufacturer calibration certificate.  A calibration certificate in accordance with EN ISO/IEC 17025 is
available at an additional cost.

The  recorder  is  made  in  a  small,  ergonomic  housing  with  a  modern  graphical  display  and  a  built­in
thermal printer. It is powered by a built­in battery that allows you to work without a charger for 48 hours.
Thanks to these features and wireless communication with measurement sensors, the device is fully
mobile and comfortable in everyday use. The set includes a car holder for mounting the device in the
driver's cabin and a car charger.
The recorder has 4 temperature measurement channels and 4 signaling channels for door opening
by the 1400mAh (removable) battery with

power  supply  from  vehicle  installation  12...24V  DC

±10%(battery life minimum one year). Each wireless sensor has a built­in temperature probe and the
ability  to  connect  the  door  open  sensor.  For  each  wireless  sensor,  you  can  also  connect  a  one
additional temperature probe via a 10mb cable sensor (Cable sensor DR203). 

 As a result, the

wireless sensor can,  for example, be mounted directly in the refrigeration chamber and measure the
ambient  temperature and,  in  addition,  the  second  temperature  can  be  measured  by  a  cable  probe
inserted into the refrigerator compartment or another fridge. 

After  connecting  the  door  limit

sensor,  each  chamber  door  open  and  close  operate  can  be  signaled  and  recorded.  Sensors  are
designed  to  work  in  hard  environmental  conditions  (low  temperatures,  high  humidity)  with  IP­65
protection. Cable probes with stainless steel measuring tips allow direct food contact.
DR­203  is  designed  to  monitor  and  record  temperature.  Built­in  non­volatile  memory  allows  you  to
record 125,000 measurements points (memory: 3 years at the memorization frequency of 15 minutes).
The interval for saving data to the memory can be set in the range from 1 min to 24 hours. When the
memory is  full, the recorder works in a loop, the oldest samples 

 

are 

overwritten 

by 

new

measurements points.
The recorder can work in one of two modes:
­ continuous registration
­ registration of deliveries (only during the course)
In  the  first  mode,  the  device  records  the  measurements  all  the  time  and  can  save  data  even  after
switching off the recorder (if the  Auto­OFF parameter set = NO) or loss of communication with radio
sensors. It is possible thanks to the sensor's cache memory (1000 measurements points), which saves
the data to it's own memory and sends it after regaining communication with the recorder.
In the second case, the registration data process is switched on and off with the every start and stop
button operate, which simultaneously marks the start and end of the course.
During  operation,  the  recorder  indicates  the  current  temperature  of  the  sensors,  time  and  alarm
thresholds messages. After pressing the info button, you can display the state of the sensors and the

?

measured since the device was turned on. The built­in

menu allows for a wide configuration of the device:
­ temperature alarm thresholds for each sensor
­ sound signaling of alarms
­ entering the names of sensors and user descriptions in the header

and footer of the print report by built in printer

­ choosing a language, setting the date, time and time zone
­ selection of the registration method and it's parameters
­ bluetooth communication settings
The parameters menu is divided into two groups:
­ basic for the driver
­ advanced for the service department
Access to the service department menu can be password protected.  After entering the password, the
memory data can be deleted and all parameters settings can be restored to the factory settings.

2

Summary of Contents for DR-203

Page 1: ...ace MaR Registr tory a dataloggery uv d www emareg cz shop emareg cz Pro technickou pomoc a dotazy n s kontaktujte 420 777884900 info emareg cz Registr tor teploty s tisk rnou bezdr tov p enos mezi id...

Page 2: ...perate can be signaled and recorded Sensors are designed to work in hard environmental conditions low temperatures high humidity with IP 65 protection Cable probes with stainless steel measuring tips...

Page 3: ...eration with a smartphone Bluetooth sending data to the server SMS notification PDF reports by e mail GPS location automatic change of summer time time zones temperature and door opening alarms sound...

Page 4: ...draws energy even when there is no device connected to it When not in use disconnect it to avoid discharging the battery A lithium ion battery was used to power the recorder The battery can not be dam...

Page 5: ...ile devices Free application for mobile devices allows for easy operation of the device from the smartphone screen The application allows you to monitor temperature signal alarms implement courses sen...

Page 6: ...and contribute to the protection of the environment ASSEMBLY Press the suction cup A in the designated area to the front or side window of the car making sure that the suction cup and glass are clean...

Page 7: ...of the battery recorder should last for a minimum of 3 hours The battery symbol informs about the state of charge of the recorder The device should not be completely discharged and the battery life ma...

Page 8: ...COM green radio communication BAT red low battery SIGNALING OF DIODES every60sec blinksonce communicationOK every 60 sec blinks twice communicationlost blinksonceatstartup afterinsertingthebattery eve...

Page 9: ...housing through a cable gland measuring tips of additional cable probes are made of stainless steel and allow direct contact with food the standard range of wireless sensors in open terrain is 100m W...

Page 10: ...compartment with space for thermal paper 2 micro USB port for data transfer 3 power socket 4 Service socket not used 5 The kit includes a roll of thermal paper that must be installed in the printer T...

Page 11: ...s the course is on current time temperature unit After completing the recorder installation the device must be configured The parameters menu is divided into two groups basic menu for the driver advan...

Page 12: ...to set a time earlier than the current one When the recorder has stored data in the memory the change of back date is blocked to prevent overwriting and loss of data First archive the data via USB or...

Page 13: ...ons and Auto OFF YES after turning off the recorder the sensors go into sleep mode and they do not save the data Auto OFF NO after turning off the recorder the sensors are still saving data in their c...

Page 14: ...intout under the place for a signature in which you can place additional user information e g Driver s first and last name advertising slogan or carrier s website adress Maximum 4 lines of text 19 cha...

Page 15: ...to cancel process press button After pressing the process of data removal will start Data will be lost irrevocably Data security before any change to the parameters in the service menu please make a...

Page 16: ...the recorder will display a list of all available sensors Example on the left Check the sensor s number and choose the one you want to add by pressing If it is wireless sensor with data stored in the...

Page 17: ...alue range 10 0 10 0 C minimal temperature level If the temperature reaches this level the recorder will activate buzz alarm and an alarm will be displayed Alarms will be saved in the memory and marke...

Page 18: ...OK The list of connected sensors will appear Chose a sensor to delete using OK Amessage will appear Confirm using OK or cancel deleting using menu button After removing the sensor you will be moved ba...

Page 19: ...ting window will appear as on the left Choose option Historical report and press OK If the message no data appears this means there is no data of the chosen time in the memory To cancel the printing p...

Page 20: ...4 D1234 drzwi otwarte Raport z dostawy DR 203 v 1 Numer fabryczny 20180511 www esco eu com R 00023 2018 08 22 23 31 Czas T1 C T2 T3 T4 D1234 C C C 2018 08 22 Podpis Za adunek 21 59 Roz adunek 08 00 1...

Page 21: ...ntout To register the start of delivery press button Icon will appear and message will be displayed To register the end of the delivery press Icon will go out and message will be displayed While recor...

Page 22: ...settings of the type of door opening circuit NO NC are in the service menu see 10 4 While opening the door connectors of limit sensor are opening or closing and they pass a signal of changing the posi...

Page 23: ...he recorder and connect to a USB port on your computer Open the disk in Windows Explorer On the USB disk will be created the main DR 203 folder in which they will be created subfolders with individual...

Reviews: