Adjust the system into its final position and then lock them to fix the position.
This assembly can be pushed up/down to maximize operator comfort.
A lever lock is placed on the back of the trolley near the handle.
Push the lever and act on the handle to adjust the height of the control panel.
This lever allows a vertical displacement of ±23 cm.
Rotate the LCD into its working position. Connect the probes and all
accessories.
Plug the power cable into the reliable grounding power outlet to assure
adequate grounding.
NOTE
Whenever the system has to be insulated from the mains, disconnect the
cable from the power outlet.
WARNING
When installing
MyLab
, check that the power cable is not tightly bent, that
it can’t be squashed by a misplaced foot or by heavy objects.
Probe Connections
Both imaging and Doppler probes can be connected to the two (2)
connectors, indicated by symbols EA1 and EA2.
Fig. 3-4: Probe connectors
Connector-securing devices are placed beside the probe connectors.
Make sure that the securing device is positioned in the lower position (open
position) and carefully attach the probe connector by placing the cable
feedthrough frontwards. To secure the probe, move the securing device up.
WARNING
Do not touch the probe connector pins or the system probes receptacle.
Never disconnect the probe while it is active. Press the
FREEZE
key before
disconnecting the probe.
CAUTION
Make sure to correctly align the probe connector before inserting it. Close
the securing device only after the complete insertion of the connector.
Summary of Contents for MyLabOmega
Page 1: ...Rev 04 July 2019 MyLabOmega GETTING STARTED 350035100...
Page 2: ...MyLab G E T T I N G S T A R T E D ii...
Page 5: ...MyLab G E T T I N G S T A R T E D v GETTING STARTED EC Declaration of Conformity...
Page 6: ...MyLab G E T T I N G S T A R T E D vi RED Declaration of Conformity...
Page 7: ...MyLab G E T T I N G S T A R T E D vii GETTING STARTED...
Page 8: ...MyLab G E T T I N G S T A R T E D viii...
Page 14: ...I N D E X MyLab G E T T I N G S T A R T E D xiv...
Page 26: ...I N T R O D U C T I O N MyLab G E T T I N G S T A R T E D 1 12...
Page 52: ...S Y S T E M O V E R V I E W MyLab G E T T I N G S T A R T E D 3 18...
Page 62: ...P R E P A R I N G T H E S Y S T E M MyLab G E T T I N G S T A R T E D 4 10...