EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
123 (200)
Note:
Remember to add the forward slash
/
at the end of the IP Address,
and press <Return>.
i.
Then open the tftp server,
Start
>
All Programs
>
AXH-EDA LCT
>
TFTP
server
.
j.
On the LCT window highlight the 1
st
row in the table, then select “
Apply
Configuration
”, then the National Mapping file should be seen loading on
the tftp window.
k. The
“
Status
” column entry should display “
OK
”, if it doesn’t then repeat the
process and
Apply Configuration
again until it does.
l.
The POTS card(s) will go offline and reboot, be patient and wait for them to
initialise which will take approximately 2 min. Then from the main LCT
window, right click on the selected POTS card and select
Show Actual
option, then “Actual Card is ………..” and “Slot Alarm Status:……” will be
displayed when the card is back online.
m.
Select the “
Actual Configuration
” tab. Click on “
Read
” then scroll to the
first installed POTS card.
n.
The actual results against each installed POTS card slot should be:-
Slotx Code
Slotx File
Slotx Status
United_Kingdom9 United_Kingdom9 Success
(where Slotx= slot 3, or slot 5, or slot 7, etc)
o.
Close down the window to return to the main LCT screen.