Proceed as follows:
Make sure not to come into contact with the running belt! For your safety, adjustment of the
belt must always be carried out by two persons. In case of emergency the second person has
to press the emergency stop button.
1.
Now switch on the treadmill and select MANUAL mode. Set the belt‘s running speed
to approx. 2 km/h.
2.
Fill the provided syringe with the special oil.
3.
Beneath the running belt on the side you will see a board with the injection hole.
Insert the syringe into the injection hole and slowly press the oil into the hole.
4.
Refill the syringe and repeat step 3.
5.
Then fill the syringe with air and press the air into the hole to make sure that the oil
has completely entered the system.
6.
After oiling, let the treadmill run at 5 km/h for another 5 minutes while no one is
running on the belt to allow the oil to spread on the running belt.
7.
Setzen Sie die Anzeige wieder zurück wie in Kapitel 7.4.1 Grundeinstellungen
CARDIO LINE 4000, Auswahl der Ölintervalle im Servicemenü bzw. 7.4.2 Grundein-
stellungen CARDIO LINE 4000, Menü „Service“, Einstellen des Serviceintervalls
(CARDIO LINE 4100) beschrieben
9 1
Injection hole