CARDIO LINE 4000 S/S MED/MED/SP/S SP
CARDIO LINE 4100 S/S MED/MED
Technical and visual modifications as well as misprints reserved -
© 2018
by ERGO-FIT GmbH & Co. KG
We recommend DC-isolated cables for the connection of external equipment to a CARDIO
LINE 4000 MED machine.
Always connect your machine directly to the power outlet. Do not use extension cables or
multi-outlet power strips unless they are EN 60601-1 certified.
4000 SP and 4000 S SP machines are equipped with a generator and a rechargeable
NiMH-battery for power supply. The rechargeable battery is maintenance-free and charged
during use. After starting the machine, it provides energy for the control panel. After
workout the electricity accumulated in the battery is used to operate the control panel for
about 45 seconds. Then the machine switches off automatically. The buffer time reduces
by increasing charging cycles and lifetime. To reach the target buffer time a weekly charge
(at least 1x24 hours per week) by a special charging power supply unit, which is available
with ERGO-FIT, is indispensable. If the buffer time reduces and can no longer be kept up
by charging the batteries should be replaced. Due to the self-discharge rate of the batteries
during operation at room temperature they should be changed every 2 years.
5.4.2
Cabeling
If you have connected several ERGO-FIT machines to one circuit never switch on multiple
machines. Connect the TRAC to a dedicated circuit.
⊗
Make sure that nobody can step on or stumble across the power cord.
⊗
Do not place any objects on the cord as it might get damaged.
5.4.3
Safety Cord
For the safety of our customers, the TRAC has been equipped with a safety cord. It is
attached to the user’s clothes by a clamp. If you should fall, for example, the safety cord
detaches from the corresponding magnet and the treadmill stops immediately.
2 7
Magnet
Clamp