CARDIO LINE 4000 S/S MED/MED/SP/S SP
CARDIO LINE 4100 S/S MED/MED
Technical and visual modifications as well as misprints reserved -
© 2018
by ERGO-FIT GmbH & Co. KG
1 2 3
A.6
Error Margins
FIn compliance with DIN VDE 0750-238 the following error margins apply for CYCLE and
RECUMBENT machines of the 4000/4100 MED and 4000/4100 S MED series:
1.
The read-out error for power (p) may not exceed ± 5 % of the displayed value. It
may not fall below ± 3W.
2.
The read-out error for speed (n) is set to a maximum of ± 2 min-1 above 40 min-1.
3.
The measurement device to assess the output calculated on the base of brake
torque and rotational speed of the treadle ergometer must not exceed an error
margin of 1 %..
The following figure shows the characteristic curve of the brake torque control:
The work capacity is displayed as follows:
Models
VDE 750-238
EN 957
Display right of rpm/speed
n/a
5% range
10% range
Points
10% range
10% range
Arrows
Deviation > 10%
Deviation > 10%
Rotational speed
40 50 60 70 80 90 100
100
200 300 400
Power