EPSON Stylus C50/C60/C61/C62
Revision C
Troubleshooting
Troubleshooting with LED Error Indications and Status Monitor 3 Message
60
3.2 Troubleshooting with LED Error Indications
and Status Monitor 3 Message
This section describes the LED indication, the STM3 message* and the error detection
condition when the printer detects an error condition in
each sequence/operation (such as
the power on sequence, the paper loading/feeding sequence, the ink absorption sequence,
* : The explanations for STM3 of the Stylus C50/C61/C62 are the same as the Stylus C60
completely except the followings.
1) Printer name
2) Figure of the printer
3) T-code for Bk ink cartridge (SC50 : T026, SC60/C61 : T028, SC62 : T040)
4) T-code for Col. ink cartridge (SC50/60/C61 : T029, SC62 : T041)
Table 3-3. Error indication and status monitor 3
Printer status
Indicators
Status monitor 3 message
Condition for error detection
Power
Error
Fatal error
Off
On
This error is detected when ;
1) the CR unit cannot move correctly by the
external force in each sequence/operation
2) the PF motor cannot rotate correctly while
the PF motor operates.
Maintenance request
Alt Blink
Alt Blink
This error is detected when the protection
counter A stored into EEPROM reaches the
limit (23270 points).
Summary of Contents for Stylus Color C60
Page 1: ...EPSONStylusC50 C60 C61 C62 Color Inkjet Printer SEIJ02001 SERVICE MANUAL ...
Page 11: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 33: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 66: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 93: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 134: ...C H A P T E R 5 ADJUSTMENT ...
Page 137: ...C H A P T E R 6 MAINTENANCE ...
Page 144: ...C H A P T E R 7 APPENDIX ...
Page 182: ......
Page 183: ......
Page 184: ......
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......