Power Supply Unit (C172 PSB/PSE Board) Removal
1.
Remove the upper housing. (See page 3-7.)
2.
Remove the printer mechanism. (See page 3-9.)
3.
Disconnect the power cable from connector CN1 on the C172 PSB/PSE board and the harness
from connector CN2 from the main controller board.
4.
Remove 4 (CBP 3
× 12
) screws securing the power supply unit to the lower housing; then
remove the power supply unit.
WARNING
Because the power switch is located in the secondary side of C172 PSB/PSE, the primary
side remains hot, even if power is off. Therefore, disconnect the power cable from the AC
inlet.
C1 72 PSB/PSE
CBP 3 x 12
C N 1
C N 2
Lower Hou sin g
Figure 3-7. Removing the Power Supply Unit
Disassembly and Assembly
3-12
EPSON Stylus 1500 Service Manual
Summary of Contents for Stylus 1500
Page 1: ...EPSON AMERICA INC Stylus 1500 EPSON Service Manual TM STYLUS15 ...
Page 2: ...EPSON Stylus 1500 Service Manual Revision Date 1st Printing 1 25 96 ...
Page 3: ...ii EPSON Stylus 1500 Service Manual ...
Page 105: ...Adjustments 4 2 EPSON Stylus 1500 Service Manual ...
Page 132: ...Troubleshooting 5 2 EPSON Stylus 1500 Service Manual ...
Page 149: ...Maintenance 6 2 EPSON Stylus 1500 Service Manual ...
Page 156: ...Appendix A 2 EPSON Stylus 1500 Service Manual ...
Page 166: ...Appendix A 12 EPSON Stylus 1500 Service Manual ...
Page 167: ...Figure A 3 C172 MAIN Board Circuit Diagram 2 Appendix EPSON Stylus 1500 Service Manual A 13 ...
Page 168: ...Appendix A 14 EPSON Stylus 1500 Service Manual ...
Page 172: ...Figure A 7 C172 MAIN Board Component Layout Appendix A 18 EPSON Stylus 1500 Service Manual ...
Page 174: ...Figure A 9 C172 PNL Board Component Layout Appendix A 20 EPSON Stylus 1500 Service Manual ...
Page 175: ...Figure A 10 Stylus 1500 Exploded Diagram 1 Appendix EPSON Stylus 1500 Service Manual A 21 ...
Page 178: ...Appendix A 24 EPSON Stylus 1500 Service Manual ...