Page 4
Epson Research and Development
Vancouver Design Center
S1D13503
13503READ.EXE Diagnostic Utility
X18A-B-006-05
Issue Date: 01/01/29
Comments
•
It is not necessary to specify a port address if 13503BIOS has previously been loaded.
•
13503READ will search for 13503BIOS.COM. If this program is found the port address reported by 13503BIOS will
be used. If the port address is specified on the 13503READ command line the two port addresses are compared and if
different an error message is generated.
•
13503READ will accept any port address, however, the S5U13503 can only be configured to an address in the range
of 300h through 370h.
Program Messages
ERROR: 13503 registers not responding at port address [port].
13503READ has not found an S1D13503 at the port address specified. Check the command line port setting for 13503BIOS
and/or 13503READ to ensure it is correct and re-run the program.
ERROR: 13503READ requires a port address.
13503READ has not detected 13503BIOS.COM to obtain the port address and no port address was specified on the
command line. Either specify a port address on the 13503READ command line or run 13503BIOS.COM prior to running
13503READ.
ERROR: 13503BIOS reports a port address of [port], which is different from the
specified port address of [port].
The port address entered for 13503READ is different than the one entered for 13503BIOS.COM. Specify the same port
address on the 13503READ command line as the one in 13503BIOS.COM and the physical address of the S5U13503
evaluation board and re-run the program.
WARNING: 13503BIOS state is out of sync with S1D13503 registers.
One or more of the following command line items reported by 13503BIOS does not match the values found in the
S1D13503 registers; horizontal panel size, vertical panel size, number of colors/gray shades, or panel type (single or dual).