12
Note:
Printing with this product is assumed to be receipts or the equivalent. If printing is continuously performed
with a high print ratio, the overcurrent limitation may be operated. Therefore, the printing length must not
exceed 20mm {0.79"} when printing with 100% print ratio.
(3)
AC power consumption (AC100 to 230 V / 50 to 60 Hz)
EU-m30
Operating:
Approx. 24.2 W
Standby:
Approx. 0.8 W
*Average power under operating conditions. Depends on use conditions and model.
1.11
EMI and Safety Standards Applied
(1)
Safety standards
Certified as part (component) installed and used in product: Recognized component product
*Not certified as final product: Not final product
CB (IEC60950-1/IEC62368-1)
TUV Bauart (EN62368-1)
UL cULus UL62368-1/CAN/CSA No62368-1
(2)
EMC
Europe
EMC Directive (EN55032/24) EMC Class A
Oceania
RCM AS/NZS CISPR32 Class A
North America FCC Class A, ICES-003 Class A
Scope of static electricity evaluation is shown below.
(3)
Model for specified customer
In addition to aforementioned (1) safety standards and (2) EMC, acquire the following:
CQC GB4943/GB9254 Class A
*Product has no CQC mark displayed.
Front
Rear
Figure 1.11.1 Scope of Static Electricity Evaluation
Summary of Contents for EU-m30 Series
Page 1: ...Developer s Guide Includes information on OT BU30 M00139800 EN Rev A ...
Page 9: ...2 Caution Caution Hot Surface See Appendix B Caution Sharp Edges See Appendix P ...
Page 52: ...45 4 4 Dimensions for Installing to Customer Device See Appendix M ...
Page 73: ...66 Y direction Printer support X direction Printer support ...
Page 75: ...68 Y direction Printer support X direction Printer support ...
Page 79: ...72 Figure P 3 ...