EPSON AcuLaser C1100
Revision B
TROUBLESHOOTING
FIP according to the printer message
179
FIP-33
Panel Message
Jam E
Jam D, E
Possible parts that caused the error
Troubleshooting
ROLL-REGI METAL
ROLL REGI RUBBER
2ND BTR ASSY
SHAFT-CENT 2ND
FRAME ASSY BTR
BEARING-BRUSH CAM
Photoconductor Unit
SENSOR FUSER IN
HARNESS ASSY ADC
HARNESS ASSY 2BTR SENS
CAM ASSY-2ND
SENSOR 2BTR RETRACT
PWBA MCU
HARNESS ASSY MAIN
LV/HVPS
MOT ASSY MICRO
CLUTCH ASSY REGI
HARNESS-ASSY P/H1
HARNESS-ASSY P/H2
MOTOR-PH
Step
Check
Yes
No
1
Check of the paper
Is the paper loaded in the paper tray wrinkled
or torn?
Replace with
new, dry paper.
Go to Step [2].
2
Paper size setting check
Does the size of the paper in use match the
size of the paper set on the control panel?
Go to Step [4].
Change the
paper size
setting, and
proceed to step
[3].
3
Does the error recur when a test print is
made?
Go to Step [4].
End of
procedure
4
Shape and operation check of ROLL-REGI
METAL
Open CHUTE ASSY-REAR.
Is ROLL REGI RUBBER attached correctly?
Also, does this part rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step [5].
Replace ROLL
in question.
5
Does the error recur when a test print is
made?
Go to Step [6].
End of
procedure
6
Check of paper position
Is the leading edge of the paper passing
through REGI ROLL?
Go to Step [7].
Go to Step [24].
7
Shape and operation check of 2ND BTR ASSY
Remove 2ND BTR ASSY.
(p.348)
Is 2ND BTR ASSY damaged?
Are SHAFT-CENT 2ND, FRAME ASSY
BTR and BEARING-BRUSH CAM
damaged? Does any of them operate
abnormally?
Replace 2ND
BTR ASSY and
other relevant
parts.
Go to Step [8].
8
Check after replacement of
Photoconductor Unit
Replace Photoconductor Unit.
Does the error recur when a test print is made?
Go to Step [9].
End of
procedure
9
Operation check of SENSOR FUSER IN
The voltage of P418-2
↔
P418-1 on PWBA
MCU is 5 VDC when white paper is brought
to the sensor sensing area, and becomes 0
VDC when paper is removed?
Go to Step [13].
Go to Step [10].
10
5 VDC power supply check to SENSOR
FUSER IN
The voltage of P418-3
↔
P418-1 on PWBA
MCU is 5 VDC?
Go to Step [11].
Go to Step [17].
Step
Check
Yes
No
Summary of Contents for C1100 - AcuLaser Color Laser Printer
Page 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Page 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Page 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 485: ...C H A P T E R 5 ADJUSTMENT ...
Page 491: ...C H A P T E R 6 MAINTENANCE ...
Page 510: ...C H A P T E R 7 APPENDIX ...
Page 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Page 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Page 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Page 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Page 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...