EPSON AcuLaser C1100
Revision B
DISASSEMBLY AND ASSEMBLY
FUSER
390
4.9.2 FUSER LOCK SWITCH
REMOVAL
1.
Remove FUSER ASSY.
(p.388)
2.
Remove COVER ASSY LH.
(p.295)
3.
Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
(p.341)
4.
Disconnect the connector (P/J128, blue) from FUSER LOCK SWITCH.
5.
Unclamp the two clamps fastening the harness on FUSER LOCK SWITCH to
remove the harness, and put the connector of FUSER LOCK SWITCH to the
inside the main unit from the hole on the main unit.
6.
Remove the screw (silver, with flange, tapping, 6 mm) fastening FUSER LOCK
SWITCH to the main unit.
7.
Slide FUSER LOCK SWITCH to the right, unhook the hook on FUSER LOCK
SWITCH from the hole on the main unit, and remove FUSER LOCK SWITCH.
Figure 4-97. Removal of FUSER LOCK SWITCH
C A U T I O N
When performing the following work, leave the intermediate
connector on the harness side.
C A U T I O N
When performing the following, take care not to damage FUSER
LOCK SWITCH by falling or dropping it.
Leg_Sec03_519EA
5)-2
5)-1
5)-1
6)
7)
4)
Summary of Contents for C1100 - AcuLaser Color Laser Printer
Page 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Page 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Page 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 485: ...C H A P T E R 5 ADJUSTMENT ...
Page 491: ...C H A P T E R 6 MAINTENANCE ...
Page 510: ...C H A P T E R 7 APPENDIX ...
Page 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Page 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Page 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Page 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Page 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...