4.11 ELEC
4.11.1 SENSOR HUM & TEMP
REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Disconnect connector (P/J104) from SENSOR HUM & TEMP.
3.
Remove the screw (silver, with flange, tapping, 8 mm) fastening SENSOR HUM
& TEMP to the main unit.
4.
Remove SENSOR HUM & TEMP from the main unit.
REINSTALLATION
1.
Attach SENSOR HUM & TEMP to the main unit.
2.
Fasten SENSOR HUM & TEMP to the main unit with the screw (silver, with
flange, tapping, 8 mm).
3.
Connect the connector (P/J104) to SENSOR HUM & TEMP.
4.
Attach COVER ASSY RH.
(p.301)
Figure 4-106. Removal of SENSOR HUM & TEMP
Table 4-6. Symptoms when the connector is loose
Connector
No.
Panel Indication
Symptom
Error Caused by Connector
Disconnection
P/J104
Service Req E530
Printing is not
possible.
Sensor HUM & TEMP error
Leg_Sec03_107EA
4)
2)
3)
Summary of Contents for C1100 - AcuLaser Color Laser Printer
Page 1: ...EPSON AcuLaserC1100 A4 Full Color Laser Printer SERVICE MANUAL SEPG04002 ...
Page 12: ...Schematic Diagram of Safety System Leg_Sec001_025EA ...
Page 19: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 74: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 119: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 276: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 485: ...C H A P T E R 5 ADJUSTMENT ...
Page 491: ...C H A P T E R 6 MAINTENANCE ...
Page 510: ...C H A P T E R 7 APPENDIX ...
Page 539: ...EPSON AcuLaser C1100 Revision B APPENDIX Exploded Diagrams 539 7 6 Exploded Diagrams ...
Page 562: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 1 of 4 Rev A ...
Page 563: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 2 of 4 Rev A ...
Page 564: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 3 of 4 Rev A ...
Page 565: ...Model AcuLaser C1100 LP V500 Board C567MAIN Sheet 4 of 4 Rev A ...