EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
110
Confidential
Fuser Unit
1. Disconnect the two connectors from the LVPS Unit.
2. Release the cables from the Clamps.
A5
B5
Connectors
Clamps
3. Disconnect the connector from the Main Board Assy.
4. Remove the two screws, and remove the Fuser Unit while pulling out the cables through the
holes.
A) Silver / M3x6 / P-Tite: Two pieces
Connector
A
A
Step 3
Step 4
Fuser Unit