![Epson AcuLaser M2000D Service Manual Download Page 125](http://html.mh-extra.com/html/epson/aculaser-m2000d/aculaser-m2000d_service-manual_108675125.webp)
EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
116
Confidential
Control Panel
1. Disconnect the connector from the Main Board Assy.
A3
B3
C3
D3
Connector
(CN405)
2. Open the Top Cover.
3. Remove the two screws.
A) Silver / M3x6 / S-Tite: One piece
B) Silver / M3x10 / P-Tite: One piece
4. Pull out the tab from the guide pin, and remove the Control Panel while pulling out the
cable.
B
A
Control Panel
Guide Pin
Summary of Contents for AcuLaser M2000D
Page 12: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 24: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 74: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 149: ...Confidential C H A P T E R 5 ADJUSTMENT ...