EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
100
Confidential
Controller Cover
1. Remove the screw.
A) Silver / M3x6 / S-Tite: One piece
2. Remove the Controller Cover in the direction of the arrow.
A1
B1
C1
D1
A
Controller Cover
Right Cover
1. Open the Front Cover.
2. Slightly pull out the Paper Cassette.
3. Remove the screw.
A) Silver / M3x10 / P-Tite: One piece
4. Disengage the five hooks of the Right Cover in the order from the rearmost hook to the
frontmost hook, and remove the Right Cover.
A2
B2
C2
D2
Hooks
A
Summary of Contents for AcuLaser M2000D
Page 12: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 24: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 74: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 149: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 159: ...Confidential C H A P T E R 6 MAINTENANCE ...