EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
117
Confidential
Control Panel Board
1. Remove the two screws, and remove the metal plate.
A) Silver / M3x6 / P-Tite: Two pieces
2. Remove the screw, and remove the Control Panel Board.
A) Silver / M3x6 / P-Tite: One piece
3. Disconnect the connector from the Control Panel Board.
B4
A
A
Step 1
Metal plate
A
Control Panel Board
Step 2,3
Connector
Left Cover
1. Open the Top Cover.
2. Slightly pull out the Paper Cassette.
3. Remove the three screws.
A) Silver / M3x10 / P-Tite: Three pieces
4. Disengage the six hooks of the Left Cover in the order from the rearmost hook to the
frontmost one, and remove the Left Cover.
C4
D4
Left Cover
Hooks
A
A
A