![Epson AcuLaser M2000D Service Manual Download Page 165](http://html.mh-extra.com/html/epson/aculaser-m2000d/aculaser-m2000d_service-manual_108675165.webp)
EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
APPENDIX
Connection Summary
156
Confidential
7.1.2 Board Connection Summary
LVPS UNIT
Figure 7-1. Board Diagram
Connector No.
Destination
Pin No.
Signal Name
I/O
Measured Voltage
Function
YC101
AC inlet
1
LIVE
I
AC100V
AC power source
2
NEUTRAL
I
AC100V
AC power source
YC102
Fuser heater lamp
1
HEATER COM
O
AC100V
Fuser heater lamp output
2
N.C.
-
-
Not used
3
HEATER LIVE
O
AC100V
Fuser heater lamp output
YC103
HVPS unit
1
+24V1
O
DC24V
DC24V power source
2
SGND
-
-
Ground
3
FAN
I
DC0V/24V
Left cooling fan motor: On/Off
4
THERM
O
Analog
Fuser thermistor detection voltage
5
+3.3V
I
DC3.3V
DC3.3V power source
6
HEATN
I
DC0V/3.3V
Fuser heater lamp: On/Off
7
SLEEP
I
DC0V/3.3V
Sleep mode signal: On/Off
8
ZCROSS
O
DC0V/3.3V (pulse)
Zero cross signal
9
+24V2
O
DC24V
DC24V power source via the interlock switch
YC101
YC103
YC104
YC105
YC102
Summary of Contents for AcuLaser M2000D
Page 12: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 24: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 74: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 149: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 159: ...Confidential C H A P T E R 6 MAINTENANCE ...