EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN
Revision B
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
96
Confidential
Main Board Assy.
1. Disconnect the 13 connectors from the Main Board Assy.
2. Release the cables from the Wire Clamps.
3. Remove the five screws.
A) Silver / M3x6 / S-Tite: Five pieces
4. Disconnect the 3 connectors from the Main Board Assy.
5. Disengage the hook and remove the Main Board Assy. together with the Main Board Assy.
Shield.
D3
Step 4
A
A
A
A
A
13 connectors
3 connectors
Hook
Wire Clamps
Main Board Assy.
Step 1
Step 5
6. Remove the five screws and Shield.
A) Silver / M3x6 / S-Tite: Five pieces
When replacing the Main Board Assy. with a new one, make sure to remove the
nonvolatile memory chip from the old board and insert it into the IC socket on the new
board. Be careful not to insert the chip upside down . Doing so can damage the chip.
A
A
A
A
A
Nonvolatile Memory Chip
Main Board Assy.
Main Board Assy. Shield
Summary of Contents for AcuLaser M2000D
Page 12: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 24: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 41: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 74: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 149: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 159: ...Confidential C H A P T E R 6 MAINTENANCE ...