4
When the printer is
turned on, it sounds
strange noise and the
CR unit is stopped
around the CR lock
lever.
1. Check if the Top
housing is secured with
the fixing screw at the
front side.
2. Check if the Change
lever is placed to the
printer front side.
3. Check if the ASF motor
is operated. Check the
CN11 connector and
the coil resistance for
ASF motor.
1. Secure the Housing fixing
screw at the printer front
side.
2. Turn back the Change
lever to the printer back
side with the tweezer or
small screw driver.
3. Connect the ASF motor
cable to CN11 on the
Main board.
Replace the ASF motor
with new one.
Table 3-11. Fatal Error indication
Step
No.
Detail phenomenon
Check point
Remedy
Top housing
Change lever
4
Ditto
4. If the CR lock lever is
not released even if the
ASF motor rotate in the
power on sequence,
check if one of the
gears has any damage
in the ASF motor
torque transportation
path.
Refer to Figure 2-15.
"ASF Motor Drive
Transmission Path to
the Pump Unit" to the
Pump unit.
4. Change the damaged gear
with new one.
5. If the problem is not
solved, replace the Main
board with new one.
Table 3-11. Fatal Error indication
Step
No.
Detail phenomenon
Check point
Remedy