EPSON Stylus PHOTO 895/785EPX
Revision A
Disassembly and Assembly
Preview monitor disassembly procedure
112
5.
Open the back case, remove the monitor cable connector and then detach the back
case.
Figure 4-76. Removal of the monitor cable connector
4.3.2 Removal of the control board unit
1.
Remove the back case. (Refer to 4.3.1)
2.
Remove one screw securing the control board unit.
Figure 4-77. Removal of the control board unit attaching screw.
3.
Remove three connectors attached to the control board unit.
Figure 4-78. Connectors removal
4.
Remove the control board unit.
Connector
Screw
C H E C K
P O I N T
CN602 and CN603 are open/close type connectors.
A D J U S T M E N T
R E Q U I R E D
When the control board unit is replaced, adjust as follows.
Brightness adjustment
Image pattern inspection
CN602
CN603
CN900
CN602
CN603
CN900