© EPRAD Incorporated
3.
Added new Instruction: “Alarm Off/On/Toggle”. This instruction provides an “OR” condition
between this new alarm flag and the existing automatic alarms. (So it cannot turn off the local
alarm due to an existing Major Fault condition.)
Also added Main Status Messages to help determine what caused the alarm to be asserted:
“ALARM ON: PROG dd:dd”
“ALARM ON: MACR dd:dd”
4.
Added finer control over Logging of Line Voltage readings. This screen now allows setting
“Voltage Logging Lower/Upper Threshold (Volts)” to log only when the voltage is out of this new
programmable range. For example, if the Voltage Logging Period is set for 1 minute, the voltage
is only logged if the voltage was outside of the threshold window. The logged voltage is the
highest and lowest voltage for that period.
5.
Trigger Screen now supports “In1 Rise” through “In16 Rise” and “In1 Fall” through In16 Fall” in
the “Controlled by” list. Events can now be triggered on either the “rising” or the “falling” edge
of an input. The previous version only allowed triggering on the rising edge.
6.
Added an optional dropdown list box to the web Restore screen (setRestore.htm) to allow a
restore of the first Program, Macro or Remote Device found in a file to a specific location in the
eCNA-10.
7.
Added Date and Time Stamp to Control Detail web screen data. Also added button to show or
hide the new time stamp data.
8.
Added new “Light Level” instruction. This new instruction allows control of the light level of any
light state and fade-in time. This instruction only works with the QDC-400 dimmer control cards.
9.
Fixed Light Control Zone Names Screen to correctly display and edit 16 zones names rather than
14.
10.
Added a “Light Control” web screen for preset and level overrides.
11.
Added “User Level Overrides Enable/Disable” to System Parameters configuration.
12.
Added “Virtual I/O” web screen and control logic. The 16 Virtual Outputs (VOutx) are
transmitted over Ethernet Multicast to the other eCNAs. The Virtual Inputs (VInx) are simply the
Boolean “OR” of the flags from all other eCNAs.
13.
Added display of Virtual Outputs to Remote Monitor web screen data. Also added button to show
or hide the Virtual Outputs. 0 = Virtual Output Off; 1 = Virtual Output On
14.
Added “User Key Names” web screen to allow custom key names. Up to 14 characters of text
can be used to name the user defined keys.
15.
I/O Boards “39431/39445 House/Aux” and “39432-1 Combo/39432-2 Film” now allow the Fire
Stop input to be configured for another control flag just as any other input.
Bug Fixes:
1.
Fixed the Segment and RDx instructions to allow selecting Tmr10. The previous version would
not allow saving the program if Tmr10 were selected. (Selecting " ", Tmr1, Tmr2,.. Tmr9 saved
fine.)
Version:
1.120
Downloadable File:
10V1120.zip
Date:
15 Nov 2010
Checksum:
34174
File Name:
10V1120.S29
File Size:
1.09M
Changes:
1.
Disabled Read and Write Configuration data commands from the (old) Host Program (CineSuite)
for LSN and TCP Networking. This was done to prevent configuration errors and faults due to
using this old software. Note: Some (old) Host support is still supported via Log messages and
some status screens.
2.
Added Output “Invert” Configuration for all configurable output relays.
3.
Changed 39331 Booth ENVIRONMENT relay to follow 39432 XENON Lamp Configuration. This
change allows user configuration of the 39331 ENVIRONMENT and 39332 XENON Lamp Relays
by configuring the 39432 XENON Relay. Previous versions had this flag hard coded to the
MOTOR flag (not user configurable). Note: The XENON Lamp Relay on the 39332 board can be
configured separately from the Projector Motor only if the newer 39434 I/O CPU board is used
(not the 39334 I/O CPU).
191
eCNA-10 Operation and Installation Manual Version 1.270-00