4.3.22 Setup: RVC-5 Card
Click on
RVC-5 Volume Card
under
Sound Control
in the
Setup Menu
. Use this screen to configure the
eCNA-10 for the optional RVC-5 Remote Volume Control card. The RVC-5's analog output connects to
the remote fader input of the sound processor. This card is available as a single or dual version. The
RVC-5S has one isolated fader control output. The RVC-5D has two isolated fader control outputs.
Select
Enabled
to use the card. Configure Output 1 and/or Output 2 for the type of sound processor
used. Control the volume level manually from the eCNA-10 front panel or automatically by using the
Volume
program instruction.
Sound Processors Supported
Dolby CP65
Dolby CP500
Ultra Stereo JS-20
EPRAD DSS
Sony DFP-D3000
U
Click
on the
Reset
button to put the original data back. Click the
Submit
button to save new settings to
the eCNA-10.
Note: Although the fader control output was designed to specifically match these
particular sound processor remote fader inputs, the RVC-5 may work with other models as
well.
53