© EPRAD Incorporated
This is a list of the most commonly used eCNA command messages. See Section 6 for a list and
descriptions of all CAI commands.
Message Description
Actual Message
Comment
Call an eCNA Macro
CMD,EVT,0,MAC,
d
,n,??\r\n
d
= Macro number 1 to 50
Start or Resume eCNA Program
CMD,EVT,0,STA,N,??\r\n
Set eCNA Program number
CMD,EVT,0,PGM,
d
,N,??\r\n
d
= Program number 1 to 9
Set eCNA Program number and Run
CMD,EVT,0,SPR,
d
,N,??\r\n
d
= Program number 1 to 9
Stop eCNA Program
CMD,EVT,0,STP,N,??\r\n
Cue eCNA Program
CMD,EVT,0,CUE,N,??\r\n
Cue eCNA Program
CMD,EVT,0,NXQ,
d
,N,??\r\n
d
= Next Cue number 1 to 20
Stop eCNA Program
CMD,EVT,0,STP,N,??\r\n
Abort the eCNA Program
CMD,EVT,0,ABT,N,??\r\n
Set the CAI Fault flag
CMD,EVT,0,FLT,N,??\r\n
Clear CAI Fault flag
CMD,EVT,0,CLR,N,??\r\n
Cancel eCNA Alarm
CMD,EVT,0,CNL,N,??\r\n
Reset eCNA Fault
CMD,EVT,0,RES,N,??\r\n
Start eCNA Timer
CMD,EVT,0,SGT,
d
,
mm
,
ss
,N,??\r\n
d
= Timer Number
mm
= 0 - 59 minutes
ss
= 0 - 59 seconds
Macro Editor - Trigger Cue
From the Trigger Cue window click the “+” button to create a trigger cue.
Enter an appropriate name for the trigger. It will be the name used by CineLister to insert this
Trigger Cue in a Show Playlist.
Figure 13 Trigger Cue Tab
Figure 14 Create Trigger Cue Name
183
eCNA-10 Operation and Installation Manual Version 1.270-00