© EPRAD Incorporated
4.3.28 Programs
A program is a series of instructions that are executed as they are encountered. The
Wait Cue
instruction is a special instruction that causes the program to wait for a
cue
event before continuing.
Many instructions have an associated offset time which allow time-delayed execution. The eCNA-10
can store up to nine programs. A macro is similar to a program but is used differently. The eCNA-10
can store up to fifty macros.
4.3.29 Program and Macro Instructions
Program and Macro Instructions
Instruction
Parameters / Offset Time
<< blank >>
n/a
House Lights Up
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
House Lights Down
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
House Lights Mid 1
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
House Lights Mid 2
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
House Lights None
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Stage Lights Up
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Stage Lights Down
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Stage Lights None
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Curtain Open
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Curtain Close
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Curtain None
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Slide Projector On
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
Slide Projector Off
dd:dd
dd:dd
= 0:00 to 59:59 minutes:seconds
*
Wait Cue
d
d
= 0 to 20
*
Wait
dd:dd
dd:dd
= 0:00 to 99:99 minutes:seconds
Aux
m1 m2
dd:dd
m1
= Out1:Flag Name to Out16:Flag Name
m2
= On, Off, No-op, Toggle
dd:dd
= 0:00 to 99:99 minutes:seconds
Volume
d1
dB Fade Time
d2
dd:dd
d1
= -50.0 to +10.0 dB
d2
= 0 to 10 seconds
dd:dd
= 0:00 to 99:99 minutes:seconds
m1
Lights
m2
dd:dd
m1
= House; Stage; Zone 3 to Zone 16
m2
= Up; Down; Mid 1; Mid 2; None
dd:dd
= 0:00 to 59:59 minutes:seconds
Sound:
m
dd:dd
m
= Non-Sync; Mono; SVA; SR; Digital 1; Aux 1; Digital 2; Aux 2; Mute On; Mute Off; None
dd:dd
= 0:00 to 59:59 minutes:seconds
Masking:
m
dd:dd
m
= Flat; Scope; Special
dd:dd
= 0:00 to 59:59 minutes:seconds
Projector:
m
dd:dd
m
= Digital 1 Pwr Off; Digital 1 Pwr On; Digital 1 Vid Off; Digital 1 Vid On;
Digital 2 Pwr Off; Digital 2 Pwr On; Digital 2 Vid Off; Digital 2 Vid On
dd:dd
= 0:00 to 59:59 minutes:seconds
Bypass:
m
dd:dd
m
= Off; On; No-op
dd:dd
= 0:00 to 59:59 minutes:seconds
CAI Commands:
m1 m2
m1
= Ch 1; Ch 2; Ch3
m2
= Allow; Block
Segment
m
m dd:dd
m
= Seg 0 to Seg 29
m
= Tmr1 to Tmr15
dd:dd
= 0:00 to 99:99 minutes:seconds
* Wait Event:
d
d
= 0 to 20
Call Macro:
d
m dd:dd
d
=0:No-op to 50:
m
= Tmr1 to Tmr15
dd:dd
= 0:00 to 99:99 minutes:seconds
CAI SendFx:
d1: m1
m2 dd:dd
d1
= 1 to 30
m1
= SendFx Name
m2
= Tmr1 to Tmr15
dd:dd
= 0:00 to 99:99 minutes:seconds
Lens/Masking:
m
dd:dd
m
= Flat; Scope; Special
dd:dd
= 0:00 to 59:59 minutes:seconds
Lens:
m
dd:dd
m
= Flat; Scope; Special
dd:dd
= 0:00 to 59:59 minutes:seconds
Set Timer:
m dd:dd
m
= Tmr1 to Tmr15
dd:dd
= 0:00 to 99:99 minutes:seconds
Timer:
m1 m2
m1
= 1 to 10
m2
= Pause; Resume
Display Timer:
m
m
= Tmr1 to Tmr15
**
If (flag):
m1 m2 m3
m1
= Status and Control Flags
m2
= Off; On
m3
= Then Exit; Goto 1 - 16
59
eCNA-10 Operation and Installation Manual Version 1.270-00