5.6 Status: System Control Detail
Click on
System Control Detail
in the
Status Menu
. This screen displays the status of the ten general
purpose timers and a history of executed Trigger and Macro events. This screen is useful for
developing and debugging your application. The screen will display up to 60 buffered events.
Timers
This table displays the status of the 15 General Purpose Timers (GPT).
Trigger/Macro History
This table displays the history of macros and triggers in the order they were executed.
No.
This column displays a number that increments to 99 and wraps. This is just a reference number
that helps you keep track of the data.
Type
This column displays either the trigger or the macro that was executed.
Cause
This column displays the corresponding event, trigger or communications channel that
generated or caused the macro or trigger.
Action
This column displays the macro that was executed as a result of the trigger.
Triggers are abbreviated as
T
xx
, where
xx
is the trigger number. Macros are abbreviated as
M
xx
,
where
xx
is the macro number. Programs are abbreviated as
P
x-yy
, where
x
is the program
number and
yy
is the step number.
The eCNA maintains a local buffer that stores a full tables’ worth a data. The
Clear Table
button only
clears the table, not the eCNA buffer data. The
Refresh Table
button retrieves all buffer data. The
Pause Display
button allows you to freeze the table data on the screen. The
Show Date & Time
button will show or hide the time stamp.
83