© EPRAD Incorporated
4.3.21 Setup: QDC-400 Dimmer Boards
QDC-400 dimmer control board channels must be configured for the desired lighting zone. The
‘physical’ wiring of the dimmer power modules and lights will determine how the zones are
configured. The eCNA-10 supports up to four QDC-400 dimmer control boards. The channels are
assigned to the dimmer boards as follows:
QDC-400 Dimmer Board
Channels
1
1, 2, 3, 4
2
5, 6, 7, 8
3
9, 10, 11, 12
4
13, 14, 15, 16
Click on
QDC-400 Dimmer Boards
under
Light Control
in the
Setup Menu
. Use the
Zone
list box to
select a zone to assign to a channel. Four light levels,
Up
,
Down
,
Mid 1
and
Mid 2
can be
configured from 0% to 100% for each channel. The
Fade-in Time
controls how long it takes to ramp
to that level from any other light level. The range is 0 to 99 seconds.
Click on the
Reset
button to put the original data back. Click the
Submit
button to save new settings
to the eCNA-10.
52
eCNA-10 Operation and Installation Manual Version 1.270-00