Standalone VGA Grid User Guide
7-6 Support
1. Connect to the admin interface using your preferred connection mechanism. See
Connect to the Admin
Interface
.
2. Login as admin.
3. Select the
Maintenance
link in the Configuration menu; the maintenance page opens.
4. Select the
Permanent Logs
check box.
5. Click
Apply
; the page updates to let you know the changes were applied.
6. Select the
Maintenance
link again; the maintenance page opens.
7. Click
Download permanent logs
; a zip file containting system logs begins to download.
8. From your browswer, run the allinfo script; a file is saved to your computer
226