Section 8: Using the Epilog Legend Systems
82
Cutting
Frequency
This control allows direct setting of the pulsing of the laser in
Vector Mode
. The
control allows setting from ten hertz to five thousand hertz. The lower frequencies
are normally used for perforating an edge when you do not want to completely
separate the cutout from the background. Most materials will show some difference
in edge appearance as the frequency is changed, and this is a mostly a matter of
personal preference. Recommended frequency settings for different materials are list
in the Recommended Speed and Power Setting section of this manual.
Smoothing
The smoothing control can be enabled or disabled by setting the control to
YES
or
NO
. This control only has an effect in vector mode. If your work is mostly straight
lines with very little in the way of curves (text is normally mostly curves) your
machine will process jobs faster with smoothing turned off (set to
NO
). Otherwise,
smoothing should be enabled (set to
YES
). Curves cut faster as well as being
significantly better finished with smoothing on.
Mapping
These features are enabled for specialized applications and with limited technical
support.
Low Frequency Pulsing
Higher Frequency Pulsing
Summary of Contents for LEGEND 24EX 6000
Page 2: ...ii THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 14: ...Introduction xiv THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 15: ...1 Manual Legend Setup ...
Page 16: ...2 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 36: ...Section 2 Safety 22 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 38: ...24 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 70: ...Section 6 Using Your Legend System Quick Setup 56 ...
Page 71: ...57 Manual Basic Operations and Maintenance ...
Page 72: ...58 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 86: ...Section 7 Using the Epilog Legend Print Driver 72 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 91: ...Section 8 Using the Epilog Legend Systems 77 Legend LCD Menu Headings LCD Graphic Display ...
Page 125: ...Section 10 Material Engraving Techniques 111 ...
Page 135: ...121 Manual Advanced Operations ...
Page 136: ...122 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 174: ...Section 12 Engraving Machine Maintenance 160 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 180: ...166 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 181: ...167 Manual Troubleshooting Service and Specifications ...
Page 182: ...168 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 216: ...202 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 224: ...Setting Up a Network Connection 210 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...