All rights reserved. No part of this Manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
photocopying, recording or by any information storage or retrieval system, without permission in writing from the publisher.
Doc #: EC501 / Rev. 1 / Effective Date: October 17, 2014
27
In the case that ECD is not being used due to
damage.
Place a
“DO NOT OPERATE”
tag in Model 800 cab.
Any damage must be reported to the site supervisor or
manager.
Upon repair or replacement of the faulty part(s), the “DO
NOT USE” Tag removed indicating that ECD is safe and
ready for use.
Chapter 12 Maintenance Checklist & Lock-out Procedure
MAINTENANCE CHECKLIST
Part
Schedule Maintenance
All flanges, pillow block and spockets
Grease weekly
Sealed bearing *
Every 200 hours
Hydraulic chain floor
Oil chains before any non use or storage
80-90W Gear oil floor drive gear box
Every 500 hours
Hydraulic oil
Inspect daily
Hydraulic oil and filter
Change every 500 hours
Weld structure
Inspect daily
Hydraulic hoses
Inspect daily
Hydraulic chain floor
Inspect daily
Side feeder belts
Inspect daily
* Sealed bearing require one shot only (otherwise could blow bearing seal)
LOCK–OUT PROCEDURE
!